2
Description of the appliance
2.1 Model
description
Unit type
Designated coun-
try (designation
in accordance
with ISO 3166)
Approval category
Type of gas
Nominal heat output range P (kW)
VKK GB 806/3-E-H
GB (Great Britain)
IE (Ireland)
I
2H
G20 (natural gas E)
14.7 – 84.1 (40/30 °C)
13.6 – 78.2 (80/60 °C)
VKK GB 1206/3-E-H
23.1 - 121.8 (40/30 °C)
21.3 - 113.4 (80/60 °C)
VKK GB 1606/3-E-H
28.4 - 168.2 (40/30 °C)
26.2 - 156.5 (80/60 °C)
VKK GB 2006/3-E-H
46.2 - 210.2 (40/30 °C)
43.1 - 196.8 (80/60 °C)
VKK GB 2406/3-E-H
50.4 - 252.2 (40/30 °C)
47.0 - 236.2 (80/60 °C)
VKK GB 2806/3-E-H
54.7 - 294.3 (40/30 °C)
51.0 - 275.5 (80/60 °C)
Table 2.1 Overview of types of unit
2.2 Identification
plate
The identification plate is mounted on the front of the
appliance under the front casing. It becomes visible
after the front section of the casing is removed.
Serial-Nr. 21400400100054100006000000N0
Typ B23, B23P, C33, C43, C53, C63, C83, C93
GB, IE, cat. I2H
2H, G20 - 20 mbar
P(40/30°C) =
14,7 - 84,1 kW
P(60/40°C) =
14,1
- 80,4 kW
P(80/60°C) =
13,6 - 78,2 kW
Q =
15,5 - 88,8 kW GCV (Hs)
Q =
14,0 - 80,0 kW NCV (Hi
NOx class 5
Tmax =
85°C
PMS =
6 bar
V =
5,74
BED 92/42
****
CE-0063BS3986
VKK GB 806/3-E-H
ecoCRAFT
230 V~ 50 Hz 260 W IP 20
EAN-CODE
Read the instructions fully before installing or using the appliance!
The appliance must be installed in accordance with the manufacturer's
instructions and the regulations in force and only in a suitably ventilated
space!
Please observe the maintenance instructions as outlined in the instruction
manual!
0063 08
Vaillant GmbH Remscheid / Germany
1
2
3
5
4
Fig. 2.1 Identification plate
Key
1 Serial-No.
2 Model
designation
3 Permitted flue pipes
4 Designated countries, permitted gas category
5 Technical
Data
Explanation of the model designation
The following table explains the model designation,
using the VKK GB/3-E-H as an example.
VKK GB 1206/3-E-H
Equipment
VKK
Vaillant gas-fired condensing
boiler
GB
Great Britain
120
Unit size (power in kW)
6
Gas-fired condensing boiler
3
Boiler production series
E
Exclusiv
H
Gas category I
2H
Table 2.2 Explanation of the model designation
2.3 CE
label
CE labelling shows that, based on the model overview,
the appliances comply with the basic requirements of
the following directives:
- Gas equipment directive (90/396/EEC)
- Electromagnetic compatibility directive with threshold
class B (2004/108/EEC)
- Low voltage directive (2006/95/EEC)
The appliances meet the basic requirements of the
efficiency requirements directive (Council Directive
92/42/EEC) as condensing boilers.
Installation and maintenance instructions ecoCRAFT 0020055744_08
4
2 Description of the appliance