Flat roof fitting and installation 5
0020159946_01 auroTHERM classic Installation manual
25
Vertical collector position
Installation angle 60°
Weights/rack [kg]
L
1
L
2
To secure against sliding and
lifting
To secure only against lifting
(if secured/anchored against
sliding)
Note
When there are at least two collectors in a row, the ballast loads can be re-
duced by half for the outer rack.
Basic wind speed [km/h]
Position
Building height
Building height
up to 10
m
10-18 m
18-25 m
up to 10
m
10-18 m
18-25 m
up to 72
Coast and islands
L
₁
L
₂
406
372
477
441
522
485
30
246
30
291
35
325
up to 81
Inland
L
₁
L
₂
352
319
460
424
532
494
30
212
30
280
37
325
up to 81
Coast and islands
L
₁
L
₂
516
479
607
566
664
621
35
315
45
372
52
407
up to 90
Inland
L
₁
L
₂
460
424
568
529
641
599
30
280
41
348
49
393
up to 90
Coast and islands
L
₁
L
₂
604
564
713
669
785
739
45
370
58
438
67
483
up to 99
Inland
L
₁
L
₂
568
529
677
634
785
739
41
348
54
415
67
483
up to 99
Coast and islands
L
₁
L
₂
749
704
857
809
930
879
62
461
75
528
84
573
up to 108
Inland
L
₁
L
₂
677
634
821
774
930
879
54
415
71
506
84
573
up to 108
Coast and islands
L
₁
L
₂
893
844
1002
949
1110
1054
80
551
92
619
105
686
5.1.7
Defining the rack clearances
B
D
E
A
C
F
C
D
▶
Define the rack clearances.