Flat roof fitting and installation 5
0020159946_01 auroTHERM classic Installation manual
33
5.2.3.1
n
Vertical collector position
Conditions
: Number of collectors: 4 … 6, Connected on opposite sides
2
1
▶
Insert the flow (outlet)
(1)
on one side in the upper lat-
eral opening and insert the return (inlet)
(2)
diagonally
opposite this in the lower lateral opening.
▶
Secure the connections with the clamps.
1
2
▶
Install the plugs
(1)
at the bottom of the collector.
▶
Install the plugs
(2)
at the top of the collector.
▶
Secure the plugs with the clamps.
▶
Connect the collector flow and return to the system with
the connection tubes.
▶
Check the connections for tightness.
▶
Select the opening in the collector field that is nearest to
the flow connection.
1
2
▶
On the selected collector, use a screwdriver
(1)
to push
the rubber stopper for the temperature sensor through to
the marking.
▶
Do not remove the rubber stopper.
▶
Push the temperature sensor through the rubber stopper
until you can feel significant resistance
(2)
.