41
Installation and maintenance manual atmoCRAFT
GB
12 Technical
data
Technical data
Unit
VK
654/9
VK
754/9
VK
854/9
VK
1054/9
VK
1154/9
VK
1304/9
VK
1504/9
VK
1654/9
Nominal heat output
kW
65
75
85
105
115
130
150
165
Nominal heat loading
kW
70.7
81.5
92.4
114
125
141.3
163
179.3
Minimum heat output
kW
42.2
48.7
55.2
68.2
74.7
84.5
97.5
107.5
Minimum thermal load
kW
46
53
60
74.1
81.3
91.8
106
116.3
Number of elements
8
9
10
12
13
15
17
19
Required feed pressure
1)
Pa
3
3
3
3
3
3
3
3
Exhaust gas temperature only at nominal
output
1)
°C
115
115
115
115
118
120
123
123
Exhaust gas temperature at minimum
output
1)
°C
80
80
80
80
80
80
80
80
Exhaust gas mass flow at nominal output
1)
kg/h
162
180
205
252
270
317
360
403
Exhaust gas mass flow at minimum output
1)
kg/h
144
166
187
234
256
288
335
367
CO
2
- content at nominal output
1
)
%
6.5
6.5
6.5
6.5
6.6
6.6
6.6
6.6
CO
2
- content at minimum output
1)
%
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
Water side resistance at
Δ
T = 20 K
mbar
18
25
32
44
46
52
60
68
Water side resistance at
Δ
T = 10 K
mbar
76
110
130
200
180
220
250
280
Permissible operating overpressure
bar
3
3
3
3
3
3
3
3
Nominal efficiency at 75/60 °C)
%
92.5
92.5
92.5
92.5
92.5
92.5
92.5
92.5
Feed temperature adjustable
°C
35 - 83
35 - 83
35 - 83
35 - 83
35 - 83
35 - 83
35 - 83
35 - 83
Connection values:
Natural gas E, H
i
= 9.5 kWh/m
3
m
3
/h
7.4
8.5
9.7
11.9
13
14.9
17
18.8
Liquid gas P, H
i
= 12,8 kWh/kg
2)
kg/h
5.5
6.3
7.2
8.8
9.7
11
12.7
14
Gas connection pressure:
Gas connection pressure natural gas
mbar
20
20
20
20
20
20
20
20
Gas connection pressure liquid gas
2)
mbar
37
37
37
37
37
37
37
37
Electrical connection
V/Hz
230/50
230/50
230/50
230/50
230/50
230/50
230/50
230/50
Electrical power consumption, max.
W
< 60
< 60
< 60
< 60
< 60
< 60
< 60
< 60
Feed and return connection
R
p
R 1 1/2“
R 1 1/2“
R 1 1/2“
R 1 1/2“
R 1 1/2“
R 1 1/2“
R 1 1/2“
R 1 1/2“
Gas connection
R
p
R 1“
R 1“
R 1“
R 1“
R 1“
R 1 1/4“
R 1 1/4“
R 1 1/4“
Flue gas connection
Ø mm
180
200
200
225
225
250
250
300
device dimensions:
Height
mm
1.145
1.145
1.145
1.145
1.145
1.145
1.145
1.145
Width
mm
850
930
1.010
1.170
1.250
1.410
1.570
1.730
Depth
mm
960
960
960
960
960
960
960
1.012
Weight
kg
317
343
369
421
447
499
550
601
Water content:
kg
28
31
34
41
44
51
57
73
Operating weight
kg
345
374
403
462
491
550
607
674
Category
-
EN: II
2ELL3P
; AT: II
2H3P
; GB: II
2H3P
Table 12.1 Technical data
1) With reference to thermal value H
i
2) Determined in accordance with DIN 4702 Part 8
3) Calculated value for dimensioning the chimney in accordance with
DIN
4705
4) With reference to 15 °C and 1013 mbar
5) Hamburger feed model is fulfilled
6 Determined in accordance with DIN 4708 Part 3