Assembly and installation 5
0020147164_07 aroTHERM Installation instructions
13
5.1.2.3 Selecting the installation site
▶
Observe all valid regulations.
▶
Install the product outside the building.
▶
Do not install the product:
–
Near a heat source,
–
Near flammable materials,
–
Near ventilation openings for adjacent buildings,
–
Under deciduous trees.
▶
Note the following points when installing the product:
–
Prevailing winds,
–
The visual impression on the environment
▶
Avoid places where strong winds blow on the product's
air outlet.
▶
Point the fan away from nearby windows. Install noise
protection if necessary.
▶
Install the product on one of the following supports:
–
Concrete slab,
–
Steel T-beam,
–
Concrete block,
–
Elevating socket (Vaillant accessory),
–
Wall bracket (permitted Vaillant accessory for VWL
55/2 A 230 V, VWL 85/2 A 230 V and VWL 115/2 A
230 V or VWL 115/2 A 400 V).
▶
Do not expose the product to dusty or corrosive air (e.g.
near unsecured streets).
▶
Do not install the product near ventilation shafts.
▶
Prepare the routing for the electrical lines.
dB(A)
dB(A)
▶
Note any noise emissions from the fan and compressor.