5 Assembly and installation
12
Installation instructions aroTHERM 0020147164_07
162
162
778
1103
463
1380*
437
VWL 155/2 A 230V
437
11
*
Size increases by 45
mm when using the
vibration dampers sup-
plied.
5.1.2.2 Installation clearance
C
B
D
A
A
E
0.5 m
Clearance
For heating mode
A
> 250 mm
B
> 1000 mm
C
> 120 mm*
D
> 600 mm
E
> 300 mm
*
Caution:
If the minimum clearances are not maintained, the
efficiency of the product may be affected.
▶
To guarantee sufficient air flow and to facilitate mainten-
ance work, observe the minimum clearances that are
specified above.
▶
Ensure that there is sufficient room to install the hydraulic
lines.
▶
If the product is to be installed in areas where heavy
snow falls, ensure that the snow does not accumulate
around the product and that the minimum clearances
specified above are observed. If you cannot ensure this,
install an additional heat generator in the heating circuit.
An elevating socket is available as an accessory. In order
to adapt the product to higher levels of snow, only use
the Vaillant elevating socket.