COMMISSIONING
29
5.3
Condition after the installation
Mechanical function test
After assembly and checking for correct polarity, check the mobility of the carbon brushes when they are de-
energized, the dimension when the new brush is spring-loaded and the installation dimension (distance be-
tween mounting surface and upper side of CU contact surface).
Checking after the first 100 cycles
Perform the following checks after the first 100 cycles of the system:
• Visual inspection of general condition. Replace damaged/defective parts.
• Check mechanical and electrical connections and re-tighten if necessary.
• Check the mobility of the carbon brushes and the free movement of the connection cable at the current
collector.
• Check the maximum position offset depending on the application and installation position. Exceeding the
tolerances can result in overloading of the contacts and carbon brushes
5.4
Operation/decommissioning
5.4.1
Operation
Operation is understood to be trouble-free, normal operation. Check intervals as per the maintenance sched-
ule in Chapter: „7 “. If defects occur, stop using the system to prevent damage.
5.4.2
Decommissioning
Switch off the system and secure it against restarting. Disconnect the entire power supply from the system
physically.