background image

12

13

Installation

Finish the wall by tiling up to the 

mortar guard, keep the final finished 

wall surface between the min and max 

marks.
Unscrew the 2 mortar guard screws 

and remove from the wall.

Pull out the spigot from the outlet on 

the left side of valve.

Cold inlet

Hot inlet

Outlet 1

Outlet 2

Connect cold supply to the lower left 

inlet of the valve and hot supply to the  

upper left inlet.
Connect outlet 1 to the desired channel 

e.g. to the shower head. 

Note:

 outlet 2 will be connected to the 

bath.

Mortar 

guard

Mortar guard 

screws

Spigot

Screw spigot into the outlet on the back 

of the plate. Tighten using a 8mm hex 

key.

Spigot

8mm 

hex key

Plate

Installation - Trim

Guide the handset holder with spigot attached partially onto the valve and then 

slide the cover plate over the threaded cartridge covers. Push on the cover plate 

and handset holder. Apply a thin bead of silicone around the outside to seal against 

the tiled surface. 

Handle 

shroud

Carefully slide the temperature handle onto the centre spline of the valve. While holding 

the handle in the vertical/horizontal position screw the shroud until touches the cover 

plate. The handle is etched to show alignment to the 38°c position on the plate.

Handset 

holder and 

outlet

Cover plate

Spigot

Threaded cartridge 

covers

Summary of Contents for ARRONDI TAB-128/3WO-B-ARR-CP

Page 1: ... TAB 128 3WO B ARR CP TAB 128 3WO S ARR CP ARRONDITM This installation guide covers 2 model TAB 128 3WO B ARR CP TAB 128 3WO S ARR CP Version 1 1 4 22 VADO Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 www vado com sales vado com ...

Page 2: ...ttings Regulations 1999 and Scottish Byelaws 2004 For further information contact the Water Regulations department of your local water supplier see the WRAS website www wras co uk for details or the Water Regulations Advisory Scheme by email info wras co uk or telephone 01495848454 Before making any inlet pipe connections all supply pipes MUST be thoroughly flushed to remove debris Failure to do s...

Page 3: ...4 5 Contents of Packaging Shower hose with 2 washers Handset Hex key Adaptors to x 4 Dimensions 50mm 74mm 314mm 80mm 80mm 58mm 50mm 58mm 50mm 80mm 61 5mm 61 5mm ...

Page 4: ...6 7 Installation Quick Guide 1 2 77mm 250mm 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 2 3 90mm 4 2 1 Installation Quick Guide 7 1 2 5 6 8mm ...

Page 5: ...8 9 Installation Quick Guide 8 9 Installation Quick Guide 10 11 ...

Page 6: ...rtar guard During installation please leave the mortar guard secured to the valve to avoid damage to the product and protect the internals during tiling etc Valve Mortar guard Installation Select the position for the shower valve and offer the shower valve to the wall make sure the valve is level and mark the 6 fixing points with a suitable pencil see above for dimensions Remove the shower valve f...

Page 7: ...pigot Screw spigot into the outlet on the back of the plate Tighten using a 8mm hex key Spigot 8mm hex key Plate Installation Trim Guide the handset holder with spigot attached partially onto the valve and then slide the cover plate over the threaded cartridge covers Push on the cover plate and handset holder Apply a thin bead of silicone around the outside to seal against the tiled surface Handle...

Page 8: ...e horizontal position screw the shroud until touches the cover plate Installation Handset Handset outlet Place a rubber washer into either end of the hose and attach it to the handset outlet see above Handset Place the other rubber washer into the end of the hose and screw to the handset see right Rubber washer Hose Rubber washer Handset Hose ...

Page 9: ...stem to stabilise 2 If the temperature is not 38 C proceed to reset the calibration as follows Remove the stop adaptor Ensure the step on the stop ring is located at 8 o clock Do not remove the plastic stop ring Please continue on next page Stop adapter Screw Temperature Commissioning Turn the spline of the thermostatic valve clockwise to decrease the temperature and anti clockwise to increase the...

Page 10: ...18 Notes 19 Notes ...

Reviews: