11
01.03.2017
STR 300S
E-Contr
ol
1b. Radar
It is always beneficial to calibrate the radar for an exact report. Refer to the instruction manual.
3.
Enter the required seed application rate (
kg/ha)
4.
Enter the required increase/decrease of variable
application rate in %.
5.
Place the calibration bag on the selected seed feed
housing.
6.
Press pre-fill (1) to fill the feed roller.
5.
Empty the calibration bag and put it back onto
the seed mater.
6.
Press Run (2) to fill the bag with grain.
Pulses are now counted for as long as the button
is pressed in.
7.
Weigh the contents of the bag.
8.
Enter the value (3) and E-Control will calculate
the number of pulses per kilo (4).
It is also possible to manually enter the number of pulses
per kg by selecting Calibration value (4) and then chang-
ing it to the selected value.
Refer also to Attachment 1, Sowing depth for further
advise and calibration table.
1.
2.
3.
4.
Contd. from previous page.
1.
Selection of which side you would like to calibrate
on (Left/Right).
2.
If you know that both of the output boxes produce
the same number of pulses per kilo, you can choose
to conduct a calibration on one side (Väderstad rec-
ommends always calibrating both). The value that
is entered will then be automatically saved for both
of the sections.