CeilingVIEW HD
Vaddio CeilingVIEW HD CCU Installation and User Guide - Document 341-768 Rev. A
Page 16 of 16
Appendix 3 (continued) Rear Panel Connections:
Power Supply Input:
36V 2.78 Amp power supply on a 5.5mm OD x 2.5mm ID connector.
RS-232 IN on RJ-45:
RS-232 Input from ProductionVIEW or other external RS-232 controller. NOTE: Daisy-chain control is not
supported with any of the CCU products.
RS-232 OUT / G/L Out on RJ-45:
RS-232 on Cat. 5 provide control to the CeilingVIEW Camera Module. NOTE: Genlock (G/L) is not
supported with CeilingVIEW CCU systems.
Tally on 2-pin Phoenix type connector:
Contact Closure lights LED on front panel allowing indication of which QCCU/camera combination is active in
a multi-camera/QCCU installation.
Unused Ports for the CeilingVIEW CCU Systems:
•
Power - RJ-45
•
G/L Input - BNC-F
•
Camera Feature Switches:
All of these switches should be in the down position.
•
Y-Gain
•
Distance
•
Video Outputs
•
Video RJ-45
Appendix 4:
Control Pin-outs for the Quick-Connect CCU
RS-232 IN Connector RJ-45
Pin
Signal - RS-232
1) Not
Used
2) Not
Used
3) Not
Used
4) Not
Used
5) Not
Used
6) GND
7)
RXD (from TXD)
8) TXD
(to
RXD)
RS-232 / G/L OUT Connector RJ-45
Pin
Signal - RS-232
1) Not
Used
2) Not
Used
3) Not
Used
4) Not
Used
5) Not
Used
6) GND
7)
T
XD (
to
R
XD)
8)
R
XD
(
from
T
XD)
9433 Science Center Drive, New Hope, MN 55428
Toll Free: 800-572-2011
▪
Phone: 763-971-4400
▪
FAX: 763-971-4464
www.vaddio.com
©2008 Vaddio - All Rights Reserved. Reproduction in whole or in part without written permission is prohibited. Specifications and pricing
are subject to change without notice. Vaddio, CeilingVIEW, EZCamera, Quick-Connect, WallVIEW, EZCable and PowerRite are
trademarks of Vaddio. All other trademarks are property of their respective owners. Document 341-768 Rev A.
+
G
12345678
12345678