CeilingVIEW HD
Vaddio CeilingVIEW HD CCU Installation and User Guide - Document 341-768 Rev. A
Page 14 of 16
Appendix 1:
Building Code Compliance
Camera Enclosure:
The Camera Enclosure for the new CeilingVIEW
HD features threaded inserts to attach a 1-gang
conduit box over the 2-Cat.5 connectors. This is for
use in areas of the country with strict building codes
pertaining to plenum air space (i.e. Chicago, NYC,
etc.) and use of conduit. The RJ-45 connectors for
Power/Video and Control are located to fit within the
foot print of a 1-gang junction box.
Appendix 2:
Video, Power and Control Pin-outs for the Camera Enclosure
Power/Video on RJ-45 Jack
(Figure 8)
# Pins
SD VIDEO
HD VIDEO
1)
Power
(+)
Power
(+)
2)
Power GND
Power GND
3)
Y+
Y+
4)
C+
PB+
5)
C-
PB-
6)
Y-
Y-
7)
Comp. Video +
PR+
8)
Comp. Video -
PR-
RS-232 on RJ-45 Jack
(Figure 9)
# Pins
1) DSR
2) DTR
3) Unused
4) Unused
5) Unused
6) Digital
GND
7)
RXD (from TXD of control source)
8)
TXD (to RXD of control source)
12345678
12345678
Figure 9:
RS-232C Control on RJ-45
Figure 8:
Power/Video on RJ-45
For Last in line Daisy Chain
Figure 7:
CV Enclosure with threaded
inserts to attach a conduit
box to the outside of the
CeilingVIEW HD Enclosure