background image

Model

VMC12DP

VMC12OP

Chamber 

Dimensions

Material

Stainless Steel Body 

& Transparent Lid

Stainless Steel Body 

& Transparent Lid

Seal Bar

Single 12" Bar

Single 12" Bar

Voltage

120V

120V

Wattage

1050W

950W

Plug Type

NEMA 5-15P

NEMA 5-15P

Pump Type

Dry

Oil

Pump Power

1/2 HP

2/5 HP

Pump Life

200,000+ Cycles

200,000+ Cycles

Vacuum Time

5-90 Seconds

5-90 Seconds

Seal Time

0-6 Seconds

0-6 Seconds

Features

• Digital Vacuum Pressure Display

• Traditional Analog Pressure Gauge

• Removable 

Seal Bar

• No Hassle 

Dry Pump

• Adjustable Vacuum And Seal Time

• Digital Vacuum Pressure Display

• Traditional Analog Pressure Gauge

• Removable 

Seal Bar

• Easy Check and Fill Oil Pump

• Adjustable Vacuum And Seal Time

Certifications

ETL

ETL

9.

Summary of Contents for VMC12DP

Page 1: ... 186VMC12DP 12 Seal Bar 120V 1050W 186VMC12OP 12 Seal Bar 120V 950W 08 2020 ...

Page 2: ...2 Food Storage and Safety Information 3 Control Panel 4 Setup Instructions 5 Operating Instructions 6 Maintenance Guide 7 Troubleshooting 8 Model Specifications 9 Warranty 10 ...

Page 3: ...d then submerge in cold water to stop the cooking process to kill any enzymes that may cause out gassing when vacuumed IMPORTANT NEVER vacuum pack garlic fungi like mushrooms or soft cheese like Brie Camembert and Ricotta A dangerous chemical reaction takes place when air is removed causing them to be extremely dangerous if ingested FOOD TYPICAL STORAGE VACUUM FRIDGE STORAGE VACUUM FREEZER STORAGE...

Page 4: ... vacuum process 4 LED Display Displays current cycle time in seconds 5 Up Down Arrow Buttons Press to increase decrease the vacuum or sealing time 6 ON OFF Button Can also be used as an emergency stop button 7 Start Button Press to begin the indicated process 8 Seal Button Press to begin the sealing process manually for fragile foods 9 Set Button Press to set the vacuum or sealing time then use th...

Page 5: ...ngs for Vacuum or Sealing Once selected the current time setting will appear on the LED Screen The unit s standard settings are Vacuum Time 40 Seconds Sealing Time 1 2 Seconds 2 Once the setting is selected you can increase or decrease the time by pressing the Up or Down arrow buttons accordingly The new time settings will appear on the screen and be saved to the machine Note For setting the Vacuu...

Page 6: ...s and the lid releases Note Some models have a manual Seal or Stop button that can be used to seal the pouch immediately This is useful when vacuuming fragile foods to prevent crushing 4 Inspect the pouch to ensure desired vacuum and seal is achieved Vacuum Quality If the quality of vacuum is not adequate or if the pouch is not tight enough inspect the pouch for air pockets or air leaks If no leak...

Page 7: ...ill bolt located on the vacuum pump using a wrench or similar tool 7 Fill the pump with oil until the level is at least halfway up the sight glass Approx 3 5oz of oil 8 Replace the oil fill bolt on the vacuum pump and then replace the back panel on the unit 9 The oil has successfully been replaced and the unit is ready to use After each day s use or when the machine is dirty remove the seal bar an...

Page 8: ...e the surface of the seal bar and inside of the bag and try again Bag loses vacuum after being sealed Check for sharp items such as bones stems cloves and others that can puncture the bags cover them with a folded paper towel and vacuum in a new pouch Some fruits and vegetables can release gases if not properly prepared before storing Make sure to blanch or freeze food before packaging If in doubt...

Page 9: ...ump Power 1 2 HP 2 5 HP Pump Life 200 000 Cycles 200 000 Cycles Vacuum Time 5 90 Seconds 5 90 Seconds Seal Time 0 6 Seconds 0 6 Seconds Features Digital Vacuum Pressure Display Traditional Analog Pressure Gauge Removable Seal Bar No Hassle Dry Pump Adjustable Vacuum And Seal Time Digital Vacuum Pressure Display Traditional Analog Pressure Gauge Removable Seal Bar Easy Check and Fill Oil Pump Adjus...

Page 10: ...ed service agency Equipment where the serial number plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and damage due to improper maintenance wear and tear misuse abuse vandalism or Act of God Any action for breach of this warranty must be commenced within 1 year of...