146
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
P2.4.3.4
AI1 custom minimum setting ID321
“AI1 Custom Min”
P2.4.3.5 AI1 custom maximum setting ID322
“AI1 Custom Max”
P2.4.4.4
AI2 custom minimum setting ID326
“AI2 Custom Min”
P2.4.4.5
AI2 custom maximum setting ID327
“AI2 Custom Max”
These parameters set the analogue input signal for any input signal span within -160...160%. For
example, if the signal input scaling is set to 40%...80%, the reference can be changed
from 8 mA (for Minimum Frequency) to 16 mA (for Maximum Frequency).
P2.4.3.6
AI1 Reference scaling, minimum value
ID303
“AI2 RefScale Min”
P2.4.3.7
AI1 Reference scaling, maximum value
ID304
“AI2 RefScale Max”
P2.4.4.6
AI2 reference scaling, minimum value
ID393
“AI2 RefScale Min”
P2.4.4.7
AI2 reference scaling, maximum value
ID394
“AI2
RefScale Max”
Additional reference scaling. Analogue input reference scaling can be set to a different
value than the minimum and maximum frequency.
Reference [Hz]
Analogue
Input
100 %
0 %
Min Freq
0 Hz
Max Freq
60 Hz
47 Hz
Ref Scale
Max
24 Hz
Ref Scale
Min
Reference [Hz]
Analogue
Input
100 %
0 %
Min Freq
0 Hz
Max Freq
60 Hz
47 Hz
Ref Scale
Max
24 Hz
Ref Scale
Min
40 %
Custom
Min
80 %
Custom
Max
P2.4.3.8 Analogue Input 1 joystick input dead zone ID382
“AI
1
JoysDeadZone”
P2.4.4.8 Analogue Input 2 joystick input dead zone ID395
“AI2 JoysDeadZone”
The small values of the reference around zero can be ignored by setting this value
greater than zero. When the reference lies between zero and ± this parameter, it is
forced to zero.
+10 V
+100 %
Max Freq
- Max Freq
Analogue Input
Reference
-10 V
-100 %
+10 %
-10 %
AI Joystick
DeadZone
= 10 %
Summary of Contents for apfiff09 marine