CONDENSATE WATER MANUAL DRAINING
In cool and dry mode condensate is formed, which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the housing. The condensate
ought to be drained regularly. If too much condensate accumulates, the device switches off
and indicates this via the FL indication on the segment display (29).
1.
Carefully transport or wheel the device to a suitable location for discharging the
condensate or position a suitable collection container under the condensate water drain
(12).
2.
Unscrew the sealing cap from the condensate water drain (12).
3.
Remove the rubber plug.
4.
Slightly tilt or incline the device towards the drain or collection container.
5.
Let the condensate run off completely.