background image

 

7.

 

Powering on the UPS   

NOTE:

 The battery will charge fully during the first five hours of normal operation. Full battery 

run capability is not possible during the initial charge period. 

 

Press the ON/Mute button on the front panel 

for two seconds

 to turn on the power to the 

UPS.   

 

8.

 

Install software 

For optimal computer system protection, install UPS monitoring software to fully configure UPS 

shutdown. Please follow steps below to download and install monitoring software. 

   
1. Go to the website 

https://www.v7world.com/ups-downloads

 

2. Select ViewPower software for your operating system to download the software.   

3. Follow the on-screen instructions to install the software. 
 

1.4 Internal Battery Replacement 

 

Note:

 This UPS is equipped with internal batteries and only a trained technician should replace 

the batteries.

 

Replace with V7 Replacement Battery Cartridge RBC1RM2U3000V7 

Replace the batteries if icons 

  and 

  are flashing in the LCD display and alarm is 

sounding every 2 seconds. 

Do not disconnect battery connectors under load. To remove input power to change the 
batteries, press the OFF button on the front panel for two seconds to power off the UPS and 
switch off utility power where the UPS is connected.

 

DO NOT DISCONNECT the batteries while the UPS is in Battery mode.   
A small arc may occur when connecting the internal batteries. This is not harmful to the UPS or 
personnel. Connect the cables quickly and firmly. 

CAUTION - Risk of electric shock

. After the UPS is disconnected from the mains (building 

wiring outlet), internal components are still connected to the battery and pose an electric 
hazard. 

Before performing service and/or maintenance, disconnect the batteries and verify that no 
current or hazardous voltage exists in the terminals of high capability capacitors. 

To avoid electrical shock, turn off the unit and unplug it form the AC power source before 
servicing the battery 

CAUTION - Risk of electric shock

. The battery circuit is not isolated from the input voltage. 

Hazardous voltages may exist between the battery terminals and the ground. Before touching, 
please verify that no voltage is present. 

CAUTION

 - Do not dispose of batteries in a fire, they could explode.   

CAUTION

 - Do not open or mutilate batteries. Released electrolyte is harmful to the skin and 

eyes and may be toxic. 

Summary of Contents for UPS2URM3000DC-NC-1N

Page 1: ...UPS2URM3000DC NC 1N User Guide...

Page 2: ...Modem surge protection 5 USB communication port 6 RS 232 communication port 7 SNMP intelligent port 8 Emergency power off function connector EPO 9 External battery connection not supported 1 1 Operat...

Page 3: ...t connecting battery wires Before installation of the UPS please follow the steps below to re connect the battery wires Rack Mount Installation Caution DO NOT use the mounting brackets to lift the uni...

Page 4: ...mm in the rear of the UPS Operate at or below a maximum altitude of 3000m for normal operation at full load 2 UPS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoi...

Page 5: ...ing software installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with an SNMP Network card When installing either SNMP for advanced communications an...

Page 6: ...power to change the batteries press the OFF button on the front panel for two seconds to power off the UPS and switch off utility power where the UPS is connected DO NOT DISCONNECT the batteries while...

Page 7: ...rior to connecting or disconnecting battery terminals Remove battery grounds during installation and maintenance to reduce the risk of shock Remove the connection from ground if any part of the batter...

Page 8: ...onfirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCD message for input voltage input frequency input current battery voltage battery current batter...

Page 9: ...oad current and load percent k kilo W watt V voltage A ampere percent centigrade degree Hz frequency Load information Indicates the load level by 0 24 25 49 50 74 and 75 100 Indicates overload Program...

Page 10: ...lay content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss AO Active open AC Active close EAT Estimated autonomy time RAT Running autonomy time SD Shutdown OK OK ON ON BL Battery...

Page 11: ...125VAC 127 presents output voltage is 127VAC 127VAC is not applicable in US region l 02 Frequency Converter enable disable Interface Setting Parameter 2 Enable or disable converter mode CF ENA convert...

Page 12: ...eptable high voltage point and acceptable low voltage point for Bypass mode by pressing the Down key or Up key HLS Bypass high voltage point For 100 110 115 120 125 127VAC models 120 140 Set the high...

Page 13: ...or programmable outlets which connect to non critical devices on battery mode Default 999 l 11 Autonomy limitation setting Interface Setting Parameter 2 Set the backup time on battery mode for general...

Page 14: ...o 2 40V cell Default 2 36V cell l 15 Charger float voltage setting Interface Setting Parameter 2 Set the charger float voltage 2 20 2 33 Set the charger float voltage from 2 20 V cell to 2 33V cell De...

Page 15: ...he UPS will bypass voltage to output for energy saving The UPS also charges the battery in ECO mode Frequency Converter mode When input frequency is within 40 Hz to 70 Hz the UPS can be set to a const...

Page 16: ...Over input current Sounds 2 beeps every 10 seconds Battery is not connected Sounds every 2 seconds Over Charge Sounds every 2 seconds Site wiring fault Sounds every 2 seconds EPO enable Sounds every 2...

Page 17: ...t v7 world com Fault code 28 is displayed on the LCD and the alarm is continuously sounding Battery voltage is too low or there is a charger fault Contact your reseller or techsupport v7 world com The...

Page 18: ...ing of a connected external battery pack for short circuited Fault code 45 is displayed on the on the LCD display and the alarm is continuously sounding No charger output and battery voltage is less t...

Page 19: ...aveform Batt Mode Pure Sinewave EFFICIENCY AC Mode 91 full charged battery ECO Mode 96 full charged battery Battery Mode 90 BATTERY Battery Type 12V 9AH Number 6 Recharge Time 3 hours recover to 95 ca...

Page 20: ...or near heat sources l Avoid blocking ventilation holes in the UPS enclosure 7 3 Installation l Do not connect appliances or devices which can overload the UPS system e g laser printers l Route cables...

Page 21: ...electrically live and dangerous l Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the termi...

Reviews: