6 - CONTROL PANEL

When power is on, the control unit checks that display correctly 
operates by switching on all segments for 1.5 sec. 

8.8.8.8

Firmware version, e.g. 

Pr 2.4

, will be viewed in the following 

1.5 sec. 

Panel will be viewed upon completion of this test.

The control panel represents the physical status of the terminal 
board contacts and of the program mode keys: if the upper 
vertical segment is on, the contact is closed; if the lower vertical 
segment is on, the contact is open (the above picture shows 
an instance where the inputs LIMIT SWITCH, PHOTOCELL 1, 
PHOTOCELL 2, SAFETY RIBBONS 1, SAFETY RIBBONS 2 and STOP 
have all been correctly connected).

The segments indicated as REMOTE SAFETY 

show the status 

of the remote safety devices for the device connected to the ADI 
connector. 

•  If the ADI interface is not enabled (no device connected), both 

segments remain turned off.

•  If the device indicates a photocell alarm, the upper segment 

comes on.

•  If the device indicates an edge alarm, the lower segment comes 

on.

•  If the device indicates a stop alarm, both segments start 

flashing.

Points being among display digits 

show the status of 

programming push-buttons: as soon as a push-button is pressed, 
its relevant point turns on. 

The arrows on the left of the display 

show the state of the 

start inputs. The arrows light when the related input is closed.

The arrows on the display right side 

show the gate status:

•  The highest arrow turns on when the gate is into its opening 

phase. If it blinks, it means that the opening has been caused 
by a safety device (border or obstacle detector).

•  The central arrow shows that the gate is on pause.  

If it blinks, it means that the time countdown for the automatic 
closing has been activated. 

•  The lowest arrow blinks when the gate is into its closing phase. 

If it blinks, it means that the closing has been caused by a 
safety device (border or obstacle detector).

6.1 - USE OF THE DOWN, MENU AND 
UP KEYS FOR PROGRAMMING

Programming of the functions and times of the controller is 
performed using a special configuration menu that is accessed 
and explored using 3 keys, DOWN, MENU, and UP, which are 
located below the display.

m

 

CAUTION: Except in the configuration menu, pressing 

the UP key activates a START command and pressing the 
DOWN key activates a START PEDESTRIAN command.

To activate the programming modes (the display must show the 
control panel), press and hold down the MENU key until 

-PrG

 

appears on the display.

Hold down the MENU key to scroll through the 4 main menus:

-PrG

    CONTROLLER PROGRAMMING

-Cnt

   COUNTERS

-APP

    SELF-LEARNING OF WORKING TIMES

-dEF

    LOAD DEFAULT PARAMETERS

To enter one of the four main menus, just release the MENU key 
when the menu you want appears on the display.

To move through the four main menus, press the UP and DOWN 
keys to scroll through the various items. Press the MENU key to 
display the current value of the selected item and change it if 
needed.

OPENING IN PROGRESS

OPEN CONTACT

CLOSED CONTACT

START

PEDESTRIAN

START

PAUSE (GATE OPENED)
CLOSING IN PROGRESS

STOP

PHOTOCELL 1

DOWN

PHOTOCELL 2

SAFETY RIBBON 1

MENU

LIMIT SWITCH (MOTOR 2)
ENCODER (MOTOR 1)
LIMIT SWITCH (MOTOR 1)
ENCODER (MOTOR 2)
UP
REMOTE SAFETY
SAFETY RIBBON 2 

MENU

3”

3”

3”

3”

MENU

6”

MENU

9”

MENU

12”

KEY PRESSED

KEY RELEASED

Summary of Contents for CITY2+

Page 1: ...TALE PER CANCELLI AD ANTA E SCORREVOLI DIGITAL CONTROL UNIT 24V FOR LEAF SWING AND SLIDING GATES ARMOIRE DE COMMANDE NUM RIQUE 24V POUR PORTAILS VANTAILS ET COULISSANTS CUADRO DE MANIOBRAS DIGITAL 24V...

Page 2: ......

Page 3: ...SHING LIGHT 5 9 LOCK 5 10 LIMIT SWITCH AND ENCODER 5 11 EXTERNAL AERIAL 5 12 PLUG IN RECEIVER 5 13 ADI INTERFACE 5 14 ELECTRIC CONNECTIONS 6 CONTROL PANEL 6 1 USE OF THE DOWN MENU AND UP KEYS FOR PROG...

Page 4: ...e plastic case has an IP55 insulation to connect flexible or rigid pipes use pipefittings having the same insulation level Installation requires mechanical and electrical skills therefore it shall be...

Page 5: ...can be used for a signal light or a 24 V flashing light Auxiliary relay with programmable logic for courtesy light flashing light or other use ENERGY SAVING FUNCTION 5 INSTALLATION Installation of co...

Page 6: ...d receiver output of photocells 2 between terminals L8 PHOTO2 and L11 COM of the control unit Use outputs having normally closed contact mWARNING if several couples of same kind photocells are mounted...

Page 7: ...mmediately The direction of the gate at next command of START or PEDESTRIAN START depends upon the parameter STOP it inverts or continues the motion If the input STOP is disabled the command makes the...

Page 8: ...and K5 COM Connect the close limit switch to motor 2 using terminals K4 FCC2 and K5 COM Installation of encoders Connect the negative feeds BLACK cable for both encoders to terminal K5 COM Connect the...

Page 9: ...al Devices Interface interface of the control unit CITY2 allows the connection to V2 optional modules Refer to V2 catalogue or to the technical sheets to see which optional modules with ADI interface...

Page 10: ...1 OPENING Z4 Motor 1 CLOSING Z5 Motor 2 OPENING Z6 Motor 2 CLOSING B1 B2 230VAC courtesy light or flashing light POW 24V power supply POW Power supply BAT pole of the optional battery pack code 161212...

Page 11: ...ENGLISH 31 F1 L N L N F1 MAINS MAINS CITY2 CITY2 L CITY2 CITY2 L CITY2 BC OVERLOAD DOWN MENU UP BAT POW POW BAT RECEIVER...

Page 12: ...as been caused by a safety device border or obstacle detector The central arrow shows that the gate is on pause If it blinks it means that the time countdown for the automatic closing has been activat...

Page 13: ...utomation work properly and if necessary modify the configuration of the desired parameters 8 LOADING OF DEFAULT PARAMETERS If necessary it is possible to restore all the parameters to their standard...

Page 14: ...anel is jammed A START command is given This position is memorized as the close point for gate panel 2 4 3 Gate panel 1 is closed until one of the conditions listed in point 4 2 occur this position is...

Page 15: ...you can alternate the display of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup of...

Page 16: ...t NOTE By holding down the UP or DOWN keys configuration menu items will scroll fast until item FinE is viewed In this way you can quickly reach either the top or bottom of the list PARAMETER VALUE DE...

Page 17: ...e to be setup is t Ch1 NOTE To avoid that the door does not close completely we recommend to setup a longer time than t APP opening time t C2P Leaf 2 closing time during pedestrian cycle no 0 5 5 0 Du...

Page 18: ...slow down phase 50 0 70 The displayed value is the percentage of max motor power P bAt Maximum motor power during battery operation During battery operation the controller is powered with a lower vol...

Page 19: ...e last closing stretch t CvE Fast closing time after slowing down 0 0 0 0 3 0 If a slowing time other than 0 is set up it could be likely that the gate speed is not enough for the lock to fasten durin...

Page 20: ...s generally used no no Function deactivated The gate closes after the time set for the function Ch AU 0 5 20 0 The gate closes after the setup time PA tr Pause after transit Per rendere minimo il temp...

Page 21: ...nput STOP stops the gate pressing the command START the gate continues the motion invE The command STOP stops the gate at the next START the gate starts moving in the opposite direction Fot1 Photocell...

Page 22: ...led for optical safety edges rESi Test enabled for conductive rubber safety edges FC En End of Stroke Inputs no no End of stroke inputs are disabled L SW End of stroke equipped with a normally close s...

Page 23: ...ing on the control unit disconnect through the disconnecting switch on the power line and remove the power supply terminal 2 Be sure that there is no voltage break upstream the control unit 3 Check wh...

Page 24: ...nected even if they are not enabled for a few instants after movement of a gate panel This means that the connection to the encoder for that gate panel is reversed Exchange terminal K1 with K2 or K3 w...

Page 25: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY Tel 39 0172 812411 Fax 39 0172 84050 info v2home com www v2home com...

Reviews: