IMPORTANT REMARKS

For any installation problem please contact our Customer Service 
at the 39-0172.812411 operating Monday to Friday 
from 8:30 to 12:30 and from 14:00 to 18:00.

V2 has the right to modify the product without previous 
notice; it also declines any responsibility to damage or 
injury to people or things caused by improper use or wrong 
installation.

m

 Please read this instruction manual very carefully 

before installing and programming your control unit.

•  This instruction manual is only for qualified technicians, who 

specialize in installations and automations.

•  The contents of this instruction manual do not concern the end 

user.

•  Every programming and/or every maintenance service should 

be done only by qualified technicians.

AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE 
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1

  (Machinery safety. electrical equipment 

          of machines, part 1: general rules)

EN 12445

     (Safe use of automated locking devices, test 

          methods)

EN 12453

    (Safe use of automated locking devices, 

          requirements)

•  The installer must provide for a device (es. magnetotermical 

switch) ensuring the omnipolar sectioning of the equipment 
from the power supply. The standards require a separation of 
the contacts of at least 3 mm in each pole (EN 60335-1).

•  After making connections on the terminal board, use one 

hose clamp to fix dangerous voltage wires near the terminal 
board and another hose clamp to fix safety low voltage wires 
used for accessories connection; this way, in case of accidental 
detachment of a conducting wire, dangerous voltage parts will 
not come into contact with safety low voltage ones.

•  The plastic case has an IP55 insulation; to connect flexible or 

rigid pipes, use pipefittings having the same insulation level.

•  Installation requires mechanical and electrical skills, therefore it 

shall be carried out by qualified personnel only, who can issue 
the Compliance Certificate concerning the whole installation 
(EEC Machine Directive 2006/42/CEE, Annex IIA).

•  The automated vehicular gates shall comply with the following 

rules: EN 13241-1, EN 12453, EN 12445 as well as any local 
rule in force.

•  Also the automation upstream electric system shall comply with 

the laws and rules in force and be carried out workmanlike.

•  The door thrust force adjustment shall be measured by means 

of a proper tool and adjusted according to the max. limits, 
which EN 12453 allows.

•  Connect the earthing lead of the motors to the electricity grid 

earth system.

•  Observe all necessary precautions (e.g. anti-static bracelet) for 

handling parts sensitive to electrostatic discharges.

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that CITY11 products conform to the 
essential requirements established in the following directives:

•  2004/108/CEE (EMC Directive in accordance with standards  

EN 61000-6-2, EN 61000-6-3 + EN 50336)

•  2006/95/CEE (Low Voltage Directive in accordance with 

standards EN 60335-1 + EN 60335-2-103)

•  99/05/CEE (Radio Directive in accordance with standard  

EN 301 489-3)

•  Directive ROHS2 2011/65/CE

Racconigi, 12/01/2010
V2 S.p.A. legal representative.egale della V2 S.p.A.  

Cosimo De Falco

TECHNICAL SPECIFICATIONS

Power supply

230V / 50Hz

120V / 60Hz

Max motors load

700W

700W

Max accessories load 24V

10W

10W

Working temperature

-20 ÷ +60 °C

-20 ÷ +60 °C

Protection fuse

F1 = 5A delayed F1 = 8A delayed 

Dimensions

170 x 185 x 70 mm

Weight

1200 g

Protection

IP55

Summary of Contents for CITY11

Page 1: ...not come into contact with safety low voltage ones The plastic case has an IP55 insulation to connect flexible or rigid pipes use pipefittings having the same insulation level Installation requires m...

Page 2: ...an be used with two settings 1 Photocell always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell restores the gate re opens completely 2 Photoc...

Page 3: ...closed In both modes it is possible to disable the Start command during gate opening by means of dip switch 3 Connect the start input control device cables between terminals L1 and L6 on the control...

Page 4: ...an opening command for a standard connection device with switch normally open L3 STOP command N C switch L4 Photocell N C switch L5 Edge Switch N C or resistive rubber edge L6 Commands common line L7...

Page 5: ...h the slow down function disabled DIP 5 OFF mWARNING the adjustment of times has to be made when the gate is still POWER MIN MAX WORK 50 18 2 2 45 PAUSE 150 30 2 2 90 DELAY 90 15 0 0 45 POWER motor po...

Page 6: ...upplemental time in order to compensate for the inertia of the gate 8 Photocell ON Always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell rest...

Page 7: ...cas de d tachement d un conducteur on vite que les partie en tension puissent aller en contact avec les parties faible tension de s curit Pour la connexion de tubes rigides ou flexibles utiliser des...

Reviews: