IMPORTANT REMARKS

For any installation problem please contact our Customer Service
at the number 

+39-0172.812411 

operating Monday to Friday

from 8:30 to 12:30 and from 14:00 to 18:00.

V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or
wrong installation.

Please read this instruction manual very carefully

before installing and programming your control unit.

• This instruction manual is only for qualified technicians, 

who specialize in installations and automations.

• The contents of this instruction manual do not concern the 

end user.

• Every programming and/or every maintenance service 

should be done only by qualified technicians.

AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:

EN 60204-1

(Machinery safety. electrical equipment of 
machines, part 1: general rules) 

EN 12445

(Safe use of automated locking devices, 
test methods)

EN 12453

(Safe use of automated locking devices, 
requirements)

• The installer must provide for a device (es. magnetotermical 

switch) ensuring the omnipolar sectioning of the equipment 
from the power supply.
The standards require a separation of the contacts 
of at least 3 mm in each pole (EN 60335-1).

• After making connections on the terminal board, use one

hose clamp to fix dangerous voltage wires near the terminal 
board and another hose clamp to fix safety low voltage wires 
used for accessories connection; this way, in case of 
accidental detachment of a conducting wire, dangerous 
voltage parts will not come into contact with safety low 
voltage ones.

• The plastic case has an IP55 insulation; to connect flexible

or rigid pipes, use pipefittings having the same insulation 
level. 

• Installation requires mechanical and electrical skills, 

therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the 
whole installation (EEC Machine Directive 89/392, Annex IIA).

• The automated vehicular gates shall comply with the 

following rules: EN 12453, EN 12445, EN 12978 as well
as any local rule in force. 

• Also the automation upstream electric system shall comply

with the laws and rules in force and be carried out 
workmanlike.

• The door thrust force adjustment shall be measured

by means of a proper tool and adjusted according to
the max. limits, which EN 12453 allows.

• We recommend to make use of an emergency 

button, to be installed by the automation (connected 
to the control unit STOP input) so that the gate may 
be immediately stopped in case of danger.

• Always remember to connect the earth according to 

current standards (EN 60335-1, EN 60204-1).

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that CITY1 products conform to the
essential requirements established in the following directives:

- 89/336/CEE (EMC Directive in accordance with standards 

EN 55014-1, EN 55014-2, EN 61000-3-2, 61000-3-3)

- 2006/95/CEE (Low Voltage Directive in accordance with 

standards EN 60335-1 + EN 60335-2-103)

- 99/05/CEE (Radio Directive in accordance with standard 

EN 301 489-3)

Racconigi, 12/01/2009
V2 S.p.A. legal representative. 

Antonio Cristina

TECHNICAL SPECIFICATIONS

DESCRIPTION OF THE CONTROL UNIT

The digital control unit 

CITY1

is an innovative V2 product that

guarantees a safe and reliable automation of leaf swing or
sliding gates.

CITY1

is provided with a display that, not only makes 

programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.

In compliance with the European standards concerning 
electrical safety and electromagnetic compatibility 
(EN 60335-1, EN 50081-1 and EN 50082-1) it has been 
equipped with the low voltage circuit total electric insulation
(motors included) from the network voltage.

Other characteristics:
• Automatic control for the null current relay switch.
• Power adjustment with independent wave shutting 

on both the two motors. 

• Obstacle detection by means of monitoring start 

condenser voltage. 

• Automatic learning of the operation time. 
• Operation by means of mechanical ends of stroke 

connected to the gearcase or connected in series to 
the motor. 

• Tests for safety devices (photocells, safety ribbons and 

triacs) before each opening.

• Deactivation of safety inputs through the configuration 

menu: no jumper is required for terminals concerning safety 
devices that have not been installed, yet.  You will only need 
to disable this function from its relevant menu. 

• Control unit programming can be locked through the optional

CL1

key.

• Also available in the 

CITY1-ECD

model (p/n 12G033), which 

allows you to control ENCODER-equipped 230V motors.

CITY1

CITY1-120V

Power supply

230VAC - 50Hz

120VAC - 60Hz

Max motors load

2 x 700W

2 x 500W

Duty clcle

40%

30%

Max accessories load 24V

10W

10W

Working temperature

-20 ÷ +60°C

-20 ÷ +60°C

Protection fuse

F1 = 5A

F1 = 8A

Dimensions

295 x 230 x 100 mm

Weight

1600g

Protection

IP55

Summary of Contents for CITY1

Page 1: ...IL n 170 1 EDIZ 04 03 2009 V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY tel 39 01 72 81 24 11 fax 39 01 72 84 050 info v2home com www v2home com CITY1 I...

Page 2: ...Y RIBBONS 28 LOCK 28 END OF STROKE 28 ENCODER 28 STOP 28 ACTIVATION INPUTS 29 EXTERNAL AERIAL 29 PLUG IN RECEIVER 29 OPTIONAL MODULES 29 CONTROL PANEL 30 USE OF DOWN MENU AND UP KEYS FOR PROGRAMMING 3...

Page 3: ...N 12453 allows We recommend to make use of an emergency button to be installed by the automation connected to the control unit STOP input so that the gate may be immediately stopped in case of danger...

Page 4: ...d in case of disabled obstacle sensor is described WARNING In case it has not yet fitted a start capacitor for each motor is required connect the start capacitor for motor 1 between terminals 27 and 2...

Page 5: ...good closing of doors Make use of a 12V lock Connect lock cables to terminals 20 and 21 of the control unit END OF STROKE CITY1 control unit supports the two following kinds of end of stroke end of s...

Page 6: ...f device controlling the first input between terminals 3 and 6 of the control unit Connect cables of device controlling the second input between terminals 4 and 6 of the control unit The first input f...

Page 7: ...nto its closing phase If it blinks it means that the closing has been caused by a safety device border or obstacle detector USE OF DOWN MENU AND UP KEYS FOR PROGRAMMING Control unit time and function...

Page 8: ...the doors will be activated in closing direction until the stop end or the closing end of stroke is reached Be sure that the leaves do not overlap In case NEITHER the ends of stroke NOR the obstacle s...

Page 9: ...ning phase before the relevant time expires WARNING if motor 2 is not connected this time must be set to zero in this circumstance the control unit will not consider all configurations of motor 2 and...

Page 10: ...mmand it will use this time to close the gate Max allowed time to be setup is t CH1 To avoid that the door does not close completely we recommend to setup a longer time than t APP opening time Leaf 2...

Page 11: ...motors to help the electric lock release The control unit controls the motors in reduced power in closing direction for the setup time The backlash precedes the electric lock release It is possible t...

Page 12: ...down function in order to measure both opening and closing times and to enable it again once the setup has been carried out The control unit will automatically consider the working time delay caused b...

Page 13: ...the step by step operation logic Select option APEr to set up the always open operation logic Start command during the pause This menu allows fixing the control unit conduct in case it receives a Sta...

Page 14: ...n is disabled by setting the value to zero no will be displayed the gate can be closed through the start command only in this case St PA menu setup will be ignored If the control unit receives a Stop...

Page 15: ...ns associated to the command of STOP no The input STOP is not available ProS The input STOP stops the gate pressing the command START the gate continues the motion invE The command STOP stops the gate...

Page 16: ...In some installations it may occur that the gate door passes before the photocells so breaking their beam In this case the gate cannot complete its closing cycle Through this function photocells can...

Page 17: ...eached its position of complete opening or closing no End of stroke inputs are disabled Si End of stroke inputs are enabled Motor Release on Mechanical Stop When the gate halts against the mechanical...

Page 18: ...exactly to the starting position it is possible to set an anti skid time that is added to the time calculated by the control unit in order to recover the inertia WARNING If function ASM is disabled t...

Page 19: ...d the learning cycle starts WARNING The procedure of the operation time automatic learning can be starter only if the Start inputs are set up on the STANDARD mode StAn End of Programming This menu all...

Page 20: ...cles after which the next service will be requested In case no new value is setup that is to say that the counter value is left at zero the signalling function for the service request will be disabled...

Page 21: ...0 no Pre flashing disabled it corresponds to 0 Pot1 30 100 Motor 1 power 60 60 Pot2 30 100 Motor 2 power 60 SPUn no Si Start off no Si t P So 0 5 3 0 Slowed down starting time 1 5 no no Slowed down s...

Page 22: ...no no no Function disabled F ShA FOTO2 disabling higher time i ShA FOTO2 disabling lower time CoS1 no Si Border 1 input fixed border no no CoS2 no Si Border 2 input mobile border no no FC En no Si En...

Page 23: ...ing phase N C contact 16 Common 17 18 Power output 24 VAC for photocells and other accessories 18 19 Photocell TX power supply for functional test 20 21 Electric lock 12VAC 22 23 Flashing light 230VAC...

Page 24: ...K 2 x 1 5 mm2 PG9 For cables with external from 5 to 8 mm OTHER WIRINGS MULTIPOLAR n x 0 25 0 5 mm2 n depending on the number of wirings to be made PG9 For cables with external from 5 to 8 mm PG11 For...

Page 25: ...sure that photocells are powered and working when you interrupt their beam you should hear the relay tripping Error 4 After few centimeters during the opening phase the gate stops and the display show...

Page 26: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY tel 39 01 72 81 24 11 fax 39 01 72 84 050 info v2home com www v2home com...

Reviews: