TO CONNECT CALYPSO WITH CONTROL UNIT

m

WARNING: always remember to connect the earth according

to current standards (EN 60335-1, EN 60204-1).

EMERGENCY RELEASE

In case of a blackout, the gate can be
operated directly from the motor. Insert the key
supplied in the lock, perform 1/2 of a turn.
To restore the automation, simply rotate the
key in closed position and insert the provided
plastic cover onto the lock.

1

YELLOW - GREEN 

GND

2

BLUE (230V mod.)
WHITE (120V mod.)

COMMON

3

BLACK

CLOSING

4

BROWN

OPENING

12

  

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Calypso400

Page 1: ...NOTICES D EMPLOI ET D INSTALLATION NICHT UMKEHRBARER ELEKTROMECHANISCHER ANTRIEB F R FL GELTORE BEDIENUNGSANLEITUNGEN UND INSTALLATION OPERADOR ELECTROMECANICO IRREVERSIBLE PARA CANCELAS BATIENTES INS...

Page 2: ...urrent A 1 1 2 2 Full load current A 1 4 1 4 2 8 2 8 Maximum Power W 300 300 300 300 Capacitor F 8 8 25 25 Max travel mm 400 500 400 500 Operating speed m s 0 016 0 016 0 018 0 018 Maximum thrust N 26...

Page 3: ...PS The new series of actuadors CALYPSO has been devised to serve gates up to 500 Kg with leaf up to 3 meters wide look at the table technical data Before proceeding with the installation please make s...

Page 4: ...40 150 140 1000 60 170 150 990 80 190 150 980 100 200 150 980 120 210 140 980 140 250 120 1010 100 20 130 170 970 40 150 180 960 60 170 180 960 80 190 170 970 100 210 140 990 110 20 130 190 950 40 15...

Page 5: ...the actuators Position CALYPSO on the brackets and fix the pins no 1 and no 2 with seeger see the picture Open and close the swings repeatedly manually to verify the absence of frictions between gate...

Page 6: ...CY RELEASE In case of a blackout the gate can be operated directly from the motor Insert the key supplied in the lock perform 1 2 of a turn To restore the automation simply rotate the key in closed po...

Page 7: ...E POUR PORTAILS BATTANTS CUADRO DE MANIOBRA ANAL GICO PARA CANCELAS A BATIENTE QUADRO DE COMANDO ANAL GICO PARA PORT ES DE BATENTE I GB F E P IL n 252 1 EDIZ 12 11 2007 V2 S p A Corso Principi di Piem...

Page 8: ...rol unit POWER motor power WORK motor operating time 5 120 seconds m PLEASE NOTE it is recommended that operating times be set with the slow down function disabled DIP 5 OFF PAUSE pause time before au...

Page 9: ...two settings 1 Photocell always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell restores the gate re opens completely 2 Photocell NOT active d...

Page 10: ...ox half way of the gate leaf connected to motor 1 Subsequent pedestrian start commands will function according to step logic During a pedestrian cycle the start command results in the complete opening...

Page 11: ...uent closing or opening operation will not be that set by the WORK trimmer but will be equal to the time effectively elapsed plus a short supplemental time in order to compensate for the inertia of th...

Reviews: