10 - ACCESSING THE CONTROL UNIT
SETTINGS
1.
Press and hold the
OK
key until the display shows the menu
desired
-FC
Programming the limit switches (chapter 10.2)
-SEn
Automatic sensitivity adjustment (chapter 10.3)
-PrG
Programming the control unit (chapter 12)
-Cnt
Cycle counter (chapter 11)
-dEF
Loading the default parameters (chapter 8)
2.
Release the
OK
key: the display will show the first item in the
sub-menu
m
WARNING: in case no operation is carried out for
more than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
-FC
fC A
-SEn
SEnS
-PrG
En.SA
-
-
-
-
2’’
4’’
6’’
-Cnt
tot
8’’
-dEF
ESC
10’’
12’’
10.1 - PROGRAMMING THE LIMIT
SWITCHES
1.
Press and hold the
OK
button until the display shows
-FC
2.
Release the
OK
button: the display shows
FC A
(opening limit switch)
3.
Press
OK
:
FC A
flashes
4.
Press and hold the key
i
or
h
and move the gate until
reaching the position of the opening limit switch
5.
Press
OK
to confirm: the display shows
FC A
6.
Press the
i
key: the display shows
FC C
(closing limit switch)
7.
Press
OK
:
FC C
flashes
8.
Press and hold the key
i
or
h
and move the gate until
reaching the position of the closing limit switch
9.
Press
OK
to confirm: the display shows
FC C
10.
Press the
i
key : the display shows
SAvE
11.
Press
OK
: the display shows no
12.
Press the
i
key: the display shows
Si
13.
Press
OK
: the limit switches are stored and the display shows
the menu for programming the
SEnS
sensitivity reported on
the next page
NOTE: we recommend you to configure both limit switches
in a single programming session
FC C
FC C
FC A
FC A
SAvE
no
Si
-FC
SEnS