ENGLISH
- 40 -
PARAMETER VALUE
DESCRIPTION
DEFAULT
MEMO
vEL.A
Opening speed (only ATRIS1000-F)
WARNING:
It is recommended to perform the force self-learning
(
SEn
menu) each time the value of this parameter is modified.
hi
hi
High speed (20 cm/s)
Lo
Low speed (12 cm/s)
vEL.C
Closing speed (only ATRIS1000-F)
WARNING:
It is recommended to perform the force self-learning
(
SEn
menu) each time the value of this parameter is modified.
Lo
hi
High speed (20 cm/s)
Lo
Low speed (12 cm/s)
P.APP
Partial opening percentage
20
0 - 100
Percentage of travel the door performs when a partial opening command is
received.
NOTE
: Partial opening can only be controlled by radio via channel 2 of the
receiver.
St.AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
PAUS
PAUS
The door stops and goes to pause
no
The START command is ignored
ChiU
The door immediately starts closing
St.Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
StoP
Stop
The door stops and the cycle ends
APEr
The door opens again
St.PA
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a Start
command when the door is open during its pause phase
ChiU
ChiU
The door recloses
no
The START command is ignored
PAUS
The pause time is reset (if the parameter
Ch.AU
=
no
, a START command
given during the pause enables the gate closing phase)
SEn.A
Sensitivity of the obstacles sensor during the opening phase
no
no
Function deactivated
1.0A - 12.0A
When the current absorbed by the motor exceeds the set value, the control
unit detects an alarm, the gate stops and the display shows the message
SEnS
for several seconds
SEn.C
Sensitivity of the obstacles sensor during the closing phase
no
no
Function deactivated
1.0A - 12.0A
When the current absorbed by the motor exceeds the set value, the control
unit detects an alarm, reopens the gate completely and the display shows
the message
SEnS
for several seconds
Foto
Photocell input
no
no
Input disabled
Si
Input enabled during closing phase. The intervention of the photocell
causes the gate to open completely.