background image

Installation instructions

CTI4T64/74
CookTopInduction V4000
Glass ceramic hob

1065985-R01

23/04/2019

1065985-R01

6

Flush installation

The layout of the hob to be fitted may differ from the hob illustrated!

507

±1

577

±1

≥41.5

≥41.5

A

550/60

0

571

50

1

Y

Y

X

X

Ri

Z

H

501

691

Y

Y

A

507±1

≥41.5

≥4

1.

5

550/600

Z

697±1

X

X

Ri

H

CTI4T64MMSLD,

CTI4T64MMSOLD

CTI4T74MMSLD,

CTI4T74MMSOLD

Cable length 1.7 m

Cable length 1.7 m

H

≥10 

*

 

Y – Y

B

Drawer/cabinet

Side panel

B

H

≥10 

*

 

X – X

550/600

C

D

Ra

R0–5

8.5

 0

-1

8.5

 0

-0.5

8.5

8.5

+1

  0

+1

  0

Detail Z

Steel angle mounted 

with adhesive or screws

* The required clearance for ventilation must be observed!

Type

A Depends on producer

B

C/D

H

Corner radius Ra/Ri

CTI4T64MMSLD, CTI4T64MMSOLD

≥20 mm

≥75 mm

560/490

51.7 mm

5/1.5 mm

CTI4T74MMSLD, CTI4T74MMSOLD

680/490

A

Worktop depth (in combination with directly built-under oven; does not apply to small appliances)

B

Required clearance for ventilation and service replacement over the entire cut-out area.

H

Dimension from the top of the work surface to the underside of the hob (ventilation opening)

Ri

Corner radii of appliance

Ra

Outer corner radii of cut-out

Installation

1.

Create an accurate installation cut-out.

– The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Accessor-

ies).

Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the induction gen-
erator can be removed from below with the mounting plate. It must be possible to unscrew the contact-proof covers from be-
low.

2.

Prepare the cut-out and appliance in accordance with the specifications in the enclosed cementing-in instructions.

3.

Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.

4.

Connect to the electrical mains connection before inserting the appliance, if necessary.

Summary of Contents for CookTopInduction V4000 CTI4T64 Series

Page 1: ...size mounting frame 31115 CTI4T64MMSLC CTI4T64MMSOLC CTI4T64MMSLD CTI4T64MMSOLD CTI4T64MMSLU CTI4T64MMSOLU 31116 CTI4T74MMSLC CTI4T74MMSOLC CTI4T74MMSLD CTI4T74MMSOLD General notes If installing into...

Page 2: ...niche width 900 mm H61085 Surface mounted installation Designation Art no Stainless steel intermediate support for the surface mounted combination of several hobs 1014361 Black intermediate support f...

Page 3: ...e Check old installa tions If the hobs are used at an altitude of over 2 000 meters above sea level a reduced performance must be expected The appliance is equipped with a connection cable which must...

Page 4: ...550 600 Ra CTI4T74MMSLC CTI4T74MMSOLC CTI4T64MMSLC CTI4T64MMSOLC Cable length 1 7 m Cable length 1 7 m The required clearance must be observed Cut out if niche width 550 mm Type A Depends on producer...

Page 5: ...rance must be observed Type A Depends on producer B H Corner radius Ra Ri CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 20 mm 60 mm 50 mm 5 1 5 mm A Worktop depth in combination with directly...

Page 6: ...uilt under oven does not apply to small appliances B Required clearance for ventilation and service replacement over the entire cut out area H Dimension from the top of the work surface to the undersi...

Page 7: ...with directly built under oven does not apply to small appliances B Required clearance for ventilation and service replacement over the entire cut out area H Dimension from the top of the work surface...

Page 8: ...30 screw length screw length Warning glass breakage Do not overtighten screws Reinforcing slats 25 25 mm Plate for chrome nickel steel cover The installation instructions with regard to electrical and...

Page 9: ...TI4T74MMSOLC 12 mm Normal mounting frame CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 12 mm Surface mounted installation CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 10 mm Flush inst...

Reviews: