background image

Installation instructions

CTI4T64/74
CookTopInduction V4000
Glass ceramic hob

1065985-R01

23/04/2019

1065985-R01

5

Overlying installation

The layout of the hob to be fitted may differ from the hob illustrated!

490±1

≥50

≥50

A

680±1

550/60

0

=

=

=

=

Ra

571

50

1

Y

Y

Ri

H

490±1

560±1

≥50

≥5

0

A

550/600

Ra

501

Ri

H

691

Y

Y

≥10 

*

B

Y – Y

H

Drawer/cabinet

CTI4T74MMSLD,

CTI4T74MMSOLD

CTI4T64MMSLD,

CTI4T64MMSOLD

Cable length 1.7 m

Cable length 1.7 m

* The required clearance must be observed!

Type

A Depends on producer

B

H

Corner radius Ra/Ri

CTI4T64MMSLD, CTI4T64MMSOLD,
CTI4T74MMSLD, CTI4T74MMSOLD

≥20 mm

≥60 mm

50 mm

5/1.5 mm

A

Worktop depth (in combination with directly built-under oven; does not apply to small appliances)

B

Required clearance for ventilation and service replacement over the entire cut-out area.

H

Dimension from the top of the work surface to the underside of the hob (ventilation opening)

Ri

Corner radii of appliance

Ra

Outer corner radii of cut-out

Installation

1.

Create the mounting cut-out accurately.

2.

Carefully place the appliance in the mounting cut-out and push against the work surface until flat.

Summary of Contents for CookTopInduction V4000 CTI4T64 Series

Page 1: ...size mounting frame 31115 CTI4T64MMSLC CTI4T64MMSOLC CTI4T64MMSLD CTI4T64MMSOLD CTI4T64MMSLU CTI4T64MMSOLU 31116 CTI4T74MMSLC CTI4T74MMSOLC CTI4T74MMSLD CTI4T74MMSOLD General notes If installing into...

Page 2: ...niche width 900 mm H61085 Surface mounted installation Designation Art no Stainless steel intermediate support for the surface mounted combination of several hobs 1014361 Black intermediate support f...

Page 3: ...e Check old installa tions If the hobs are used at an altitude of over 2 000 meters above sea level a reduced performance must be expected The appliance is equipped with a connection cable which must...

Page 4: ...550 600 Ra CTI4T74MMSLC CTI4T74MMSOLC CTI4T64MMSLC CTI4T64MMSOLC Cable length 1 7 m Cable length 1 7 m The required clearance must be observed Cut out if niche width 550 mm Type A Depends on producer...

Page 5: ...rance must be observed Type A Depends on producer B H Corner radius Ra Ri CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 20 mm 60 mm 50 mm 5 1 5 mm A Worktop depth in combination with directly...

Page 6: ...uilt under oven does not apply to small appliances B Required clearance for ventilation and service replacement over the entire cut out area H Dimension from the top of the work surface to the undersi...

Page 7: ...with directly built under oven does not apply to small appliances B Required clearance for ventilation and service replacement over the entire cut out area H Dimension from the top of the work surface...

Page 8: ...30 screw length screw length Warning glass breakage Do not overtighten screws Reinforcing slats 25 25 mm Plate for chrome nickel steel cover The installation instructions with regard to electrical and...

Page 9: ...TI4T74MMSOLC 12 mm Normal mounting frame CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 12 mm Surface mounted installation CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 10 mm Flush inst...

Reviews: