![V-TUF RAPIDSXL110 Operator'S Manual Download Page 23](http://html1.mh-extra.com/html/v-tuf/rapidsxl110/rapidsxl110_operators-manual_3088692023.webp)
23
CHAPTER 7 - TECHNICAL DATA
7.1 ENVIRONMENTAL REQUIREMENTS
The HOT WATER CABINET hot water pressure washer has been designed and manufactured to be used
in the following environmental conditions.
• Maximum tempe90°C
• Minimum tempe1°C
• Relative humidity 80%
7.2 DIMENSIONS AND TECHNICAL DATA
Line
Mono-Phase
Three-Phase
Technical Data (I)
Units
100.12
150.15
200.15
150.21 200.21
Scope
L/min
12
15
15
21
21
Operating pressure
MPa
10
15
20
15
20
Maximum pressure
MPa
10
15
20
15
20
Power
kW
2,2
4
5.5
5,5
7,5
T° Max. inlet H2O
°C
50
Max. outlet temperature H2O
°C
90
Burner power
kcal/h
52.000
Burner fuel type
-
diesel
Fuel tank volume
litres
43
Maximum H2O input pressure
(water mains or system)
MPa
0.5
Gun repulsive force at maximum
pressure
N
49.36
Engine insulation
-
Class F
Engine protection
-
IP54
Voltage / Frequency (*)
V/Hz
230/50
400/50
Safety valve - intervention pressure
(110% Press. Max.)
Bar
110
165
220
165
220
Sound emission level:
Sound pressure at operator: LpA
(EN 3744)
K = 3 dB(A)
dB (A)
92
Sound Power: LwA (EN 3744) K
= 3 dB(A)
dB (A)
102
Hand-arm vibrations
K=1.5 M/s2 M/s2
1.94
WEIGHT
Kg.
265
265
280
280
300
DIMENSIONS (WxDxH)
mm
815x560x1650
(*) = 60 Hz version available on request