background image

4

CLASSIFICATION OF RISKS:

 

Identifies an imminent risk which could lead to 

serious or fatal injury.

Danger

Identifies a risk situation which could lead to 

serious injury.

Warning

Identifies a risk situation which could lead to 

minor injury or damage to things.

Information

PREFACE

 

You must read this manual before installing, 

starting up and using the high pressure washer.

This manual is an integral part of the product.

Warning

Read the warnings and instructions contained in 

the manual carefully as they provide important 

information on 

USER SAFETY

 and 

MAINTENANCE,

 

paying particular attention to the general safety 

regulations.

KEEP THIS MANUAL IN A SAFE PLACE FOR 

FUTURE REFERENCE.

Those operating and servicing the high pressure

washer must be aware of the contents of this 

manual.

Warning

CLASSIFICATION

 

The user must observe the conditions of use of the 

appliance prescribed by the Rules, and particularly he 

must respect the following classification:

As for the protection against electric shock, the H.P.cleaner

belongs to 

CLASS I.

The H.P. cleaner is factory set and all its safety devices 

are sealed. 

It is forbidden to alter their adjustment

values.

In the Hot water cleaner the water is heated by a burner 

feed with 

Diesel

 fuel.

The H.P. cleaner must be always used on a firm and flat 

ground, furthermore it must not be moved while it is 

working or connected to the electric supply.

Failure to observe this prescription may cause danger for

the user.

The H.P. cleaner must not be used in the presence of 

corrosive or potentially explosive atmospheres. 

(vapours or gas)

GENERAL SAFETY RULES FOR
THE USE OF HIGH PRESSURE
CLEANERS

- The electric connection must be performed by

qualified technicians who are able to work in

observance of the governing rules (in compliance

with the provisions of the IEC 60364-1 standard)

and of the manufacturer’s instructions.

A wrong electric connection may cause damage

to persons, animals or things, and the 

manufacturer cannot be considered responsible

for these.

- The H.P. cleaners with power lower than 3 kW

are equipped with a plug for connection to the

electric supply.

In this case please check if the electric power

system and the electric sockets are compatible

with the max. power of the appliance indicated

on the plate. (kW). 

In case of doubt, please apply to qualified

personnel. If the socket and the plug of the 

machine are not compatible, have the plug 

replaced with a suitable type by qualified 

personnel.

- Before connecting the machine make sure 

that the data indicated on the plate correspond 

to those of the electric supply.

- Do not use extensions to power the high

pressure washer.

If you use an extension, the plug and socket 

must be watertight. Unsuitable extensions may

be dangerous.

- The electric safety of this machine may be

assured only when it is properly connected to

an efficient grounding system in accordance with

the governing laws for electric safety. (In 

compliance with the provisions of the IEC 60364-1

standard)

Warning

Summary of Contents for HD140HOT

Page 1: ...HD140HOT Please read this manual before using the HD140HOT HOT WATER PROFESSIONAL MOBILE PRESSURE WASHER...

Page 2: ...LS and DETERGENTS suitable for cleaning all kinds of surfaces Ask your Dealer for the complete catalogue of our products TRANSLATION OF ORIGINAL INSTRUCTIONS The text has been carefully checked howeve...

Page 3: ...ALS POWER SOCKETS OR THE MACHINE IT SELF SWITCHING OF THE PUMP MOTOR ATTENTION RISK OF BURNS LIGHTING THE BURNER ATTENTION RISK OF ELECTRIC SHOCK FUEL DIESEL EARTH CHEMICHALS DETERGENT WATER INPUT DO...

Page 4: ...Failure to observe this prescription may cause danger for the user The H P cleaner must not be used in the presence of corrosive or potentially explosive atmospheres vapours or gas GENERAL SAFETY RUL...

Page 5: ...e considered as off when the omnipolar switch is in the O position or the plug is unplugged from the socket The high pressure washer is not intended for use by children adolescents or persons with red...

Page 6: ...e ventilation grilles and the heat and smoke extraction systems in the hot water cleaners Do not use the machine if the supply cable is damaged For the replacement of the damaged cable apply exclusive...

Page 7: ...ording to the European Standard PRELIMINARY OPERATIONS UNPACKING After unpacking ensure that the cleaner is undamaged If in doubt do not use the machine Contact your dealer Packaging bags boxes nails...

Page 8: ...of the detergents that can be used depending on the type of washing job to be done and the type of surface to be treated After using a detergent the detergent intake circuit must be flushed out with...

Page 9: ...ean water Dirty or sandy water corrosive chemicals and solvents can cause severe damage to the cleaner Danger Never suck up liquids containing solvents or acids in the pure state for example petrol pa...

Page 10: ...cleaner to the mains electricity supply by plugging the plug into the socket 3 Start the cleaner by turning the selector switch to pos I fig 7A Warning The high pressure water jet generates a reactio...

Page 11: ...ly turn it off by using the Solenoid switch or by unplugging the plug from the socket Water cleaners with the Total Stop device should be considered as off when the Solenoid switch is in the O positio...

Page 12: ...aner which is factory set the exhaust system must be checked The rating done by the manufacturer determines a production of exhaust gases with a CO content lower than 0 04 and a smoke content correspo...

Page 13: ...ear during use Wear may generally be detected by a drop in the working pressure of the cleaner To replace it consult your supplier and or dealer for instructions DESCALING Descaling must be carried ou...

Page 14: ...s and protect any parts that could be damaged by the accumulation of dust Grease the parts that could be damaged by drying out such as the supply hoses When bringing back into use ensure that there ar...

Page 15: ...ap open Pressure adjustment devices on lance open if present Nozzle clogged or deformed Inadequate water supply No diesel Filters clogged Boiler element coated with scale Incorrect combustion Fuel con...

Page 16: ...16...

Reviews: