INSTALLATION:

• Provide power to the required point of installation

• Remove the top cover as shown below in the image

EMERGENCY TERMINATIONS 

MAINTAINED/NON-MAINTAINED

TECHNICAL DATA

INTRODUCTION & WARRANTY

Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instruc-
tions carefully before starting the installing and keep this manual handy for future reference. If you have any 
another query, please contact our dealer or local vendor from whom you have purchased the product. They 
are trained and ready to serve you at the best. The warranty is valid for 3 years from the date of purchase. 
The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The 
company gives no warranty against damage to any surface due to incorrect removal and installation of the 
product. The products are suitable for 10-12 Hours Daily operation. Usage of product for 24 Hours a day 

would void the warranty. 

This product is warranted for manufacturing defects only.

• Using the top cover as a template, mark the location for, and drill 2 fixing holes ensuring not to infringe with 

any joists, gas or water pipes or electrical cables.

• Feed the mains cable through the cable entry hole in the top cover.

• Connect mains cable into push-fit terminal block ensuring correct polarity is observed,see the following figures 

for maintained, non-maintained and switched maintainedwiring diagram.

• Connect flying lead from battery pack to the socket on the PCB.

• Refit the exit sign to the top cover ensuring all 4 lugs lock into place.

1. Remove 2-PIN connector for 

Non-Maintained Operation

2. Connect battery lead

 

WARNING:

• This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur if this instruction is not followed

• Recommended routine test procedure in accordance with BS5266

• Daily check – check that the status GREEN LED indicator is illuminated

• Monthly functional test – simulate a mains supply failure for approx. 30 secs by operation of key switch or 

switching off a circuit breaker. Ensure normal supply is restored after test and the indicator status LED is 

illuminated

• Twice yearly conduct a one hour duration test - simulate a mains supply failure for one hour continuous test 

by operation of key switch or switching off circuit breaker. Ensure normal supply is restored after test and the 

indicator status LED is illuminated

• Annual full three hour duration test - conduct a three hour continuous duration test. Simulate a mains supply 

failure for three hour continuous test by operation of key switch or switching off circuit breaker. Ensure normal 

supply is restored after test and the indicator status LED is illuminated

• Please make sure to turn off the power before starting the installation.

• The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole 

luminaire shall be replaced.

• Replace any cracked protective shield.

• Installation should only be done by a certified electrician.

• For Indoor Use only

Model

VT-519-S

Wa�s

140

No. Of Led

16

Lumen

s

2

Working Time

>3 Hour

s

Body Type

PC

IP Ra

ng

IP20

Emergency Opera

on 

Time

>3 Hour

s

Charging Time

12 Hour

s

Ba

ery Charging 

Current

100-140mA

Ba

ery Di

s

charge 

Current

200-280mA

Ba

ery Type

Ni-Cd 3.6V,900mAh

Dimen

s

ion

380x51x195mm

Input Power

AC:220-240V,50/60Hz

3

YEA

RS

WARRANTY

*

This marking indicates that this 

product should not be disposed 

of with other household wastes.

Caution, risk of electric shock.

• Restore the supply and check that the Green LED indicator illuminates to confirm the batteries are charging. 

There are three possible reasons when the green LED indicator does not light up: 

1) there is no power supply AC220-240V,

2) the batteries are not properly connected to the PCB,

3) the batteries are not being charged.

• Allow a short period for partly charging the batteries and then isolate the mains supply to the fitting in order 

to check the correct operation of the fitting in emergency mode. After 36 hours on continuous charge (and only 

at a safe time) a mains failure should be simulated to ensure that the fitting illuminates for its rated emergency 

duration.

The luminaire will have a 1-hour backup after 14 hours charging and will be fully charged after 24 hours (first 

charge 36 hours)

MAINTENANCE

Once the luminaire no longer meets the rated emergency operation the batteries must be replaced after a 

maximum of 4 years in service.

Repairs should only be carried out by a qualified person. Please recycle disposal of replaced components where 

facilities exist. Special care should be taken if it’s required to open the fitting as the fitting may still be “live” 

even though the mains supply has been isolated. In these circumstances immediately disconnect the battery 

supply.

Servicing and cleaning should only be carried out after the fitting has been made electrically safe. Cleaning of 

luminaires should be carried out at regular intervals not only to ensure good optical performance but also 

ensure that dirt does not accumulate to such an extent as to impair the electrical or thermal safety of the 

fitting.

(Maintained)

IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: [email protected]

FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST 

DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B

ENGLISH

ENGLISH

ENGLISH

MULTI-LANGUAGE 

MANUAL QR CODE

Please scan the QR code

to access the manual in

multiple languages.

Summary of Contents for VT-519-S

Page 1: ...ircuit breaker Ensure normal supply is restored after test and the indicator status LED is illuminated Please make sure to turn off the power before starting the installation The light source of this...

Page 2: ...51x195mm AC 220 240V 50 60Hz 3 YEARS WARRANTY LED LED 1 AC220 240V 2 3 36 1 14 24 36 4 IN CASE OF ANY QUERY ISSUE WITH THE PRODUCT PLEASE REACH OUT TO US AT SUPPORT V TAC EU FOR MORE PRODUCTS RANGE IN...

Page 3: ...continuo di durata di tre ore Simulare un inter ruzione dell alimentazione di rete per un test continuo di durata di tre ore azionando l interruttore a chiave o disattivando l interruttore automatico...

Page 4: ...r s folyamatos tesztel ssel a kulcsos kapcsol vagy a megszak t kikapcsol s val Ellen rizze hogy a teszt ut n helyre ll e a norm l t pell t s s vil g t e a jelz f ny LED K rj k a szerel s megkezd se e...

Page 5: ...uchtet J hrlicher Test von voller dreist ndiger Dauer Durchf hrung eines dreist ndigen Tests von kontinuierlicher Dauer Simulieren Sie einen Netzausfall f r einen dreist ndigen Dauertest indem Sie ein...

Page 6: ...pleta de tres horas ejecute una prueba continua de tres horas Simule una falla en la alimentaci n en una prueba continua de tres horas activando el interruptor o apagando el disyuntor autom tico Despu...

Page 7: ...un essai continu d une dur e de trois heures Simuler une panne de secteur pour un essai continu de trois heures en actionnant un interrupteur cl ou en coupant le disjoncteur S assurer que l alimentat...

Page 8: ...loviti godi nji test u trajanju od tri sata izvedite trosatni kontinuirani test Simulirajte nestanak struje u trosatnom kontinuiranom ispitivanju tako to e te aktivirati sklopku ili isklju iti osigura...

Page 9: ...um exame cont nuo de tr s horas Simule uma falha na alimenta o num exame cont nuo de tr s horas ao ativar o interruptor ou ao desligar o disjuntor autom tico Ap s o exame restaure a alimenta o normal...

Page 10: ...w trzygodzinnym ci g ym te cie aktywuj c prze cznik lub wy czaj c wy cznik automatyczny Po te cie przywr normalne zasilanie i upewnij si e wska nik LED wieci WY CZY zasilanie przed przyst pieniem do...

Page 11: ...380x51x195mm AC 220 240V 50 60Hz 3 YEARS WARRANTY LED LED 1 AC220 240V 2 3 36 1 14 24 36 4 IN CASE OF ANY QUERY ISSUE WITH THE PRODUCT PLEASE REACH OUT TO US AT SUPPORT V TAC EU FOR MORE PRODUCTS RAN...

Page 12: ...n fiecare an trebuie f cut o ncercare cu o durat de trei ore ntrerupe i alimentarea de la re eaua electric respectiv pe timpul ncerc rii de trei ore pun nd n func iune ntrerup torul electric simplu s...

Page 13: ...inov nep etr it test Simulujte v padek s ov ho nap jen po dobu t hodin nep etr it ho testu spu t n m kl ov ho sp na e nebo vypnut m jisti e Po zkou ce obnovte norm ln nap jen a zkontrolujte zda sv t s...

Reviews: