TLT-2F GPS/GSM Car Tracker Instruction Manual V3.0
30/34
9. Low voltage upload
If working voltage of TLT-2F is lower than the
set value, and the device will operate “instruction to
immediately upload current position” and add “LP” auxiliary attribute into data status to show current status. The
information will be sent for 3 times with an interval of 1 minute.
10. Historical data upload function
In order to use the function in SMS mode, please switch to GPRS to set IP and APN.
1. Set historical data rewire
Instruction format: #807# user password #X##
For example: #807#0000#30##
Description: After receiving the instruction and confirming that user password is correct, TLT-2F will set
historical rewire sampling frequency as X. If X=0, the device will close historical data rewire. If X!=0, the device
will take X seconds as interval to store received GPS data. After success, it will return confirmation message to the
sender: SET SAMPLING OK.
Note: 1. X is historical rewire sampling frequency, whose defined domain is [0, 999] with second as unit.
2. Size of each data quantity is around 100B (BYTE).
3. Memory space distributed to historical data rewire is 864KB (BYTE) and stack override method is used to
update data storage. If X=30, data for about 3 days will be rewired. If X=300, data for about 30 days will be
rewired. When stored data reach 864KB, newly received data will override earlier data.
4. If power saving function is activated and TLT-2F remains static for a long time, historical rewire will be
automatically closed until TLT-2F is wakened up and GPS is turned on.
2. Instruction to set historical data upload
1>Upload 24-hour historical rewire:
Instruction format: #808# user password #24##
For example: #808#0000#24##
Description: After receiving the instruction, TLT-2F will return confirmation message: START UPLOAD 24H
HISTORICAL REWIRE. It will send historical data rewired in the past 24 hours to the server with the same format
as position information mentioned in “instruction to immediately upload current position” and information status is
SOTRAGE.
2>Read all data rewires:
Instruction format: #808#0000##