background image

The DMX512 Channel

通道说明

Channel

通道

Function

/

功能

Introduction

说明

1CH

Dimmer

/

调光

0-255 LED Dimmer Linear dimming from dark to bright 0-255

LED

调光 线性调光 由暗到量

2CH

Strobe

/

频闪

0-255 Stroboscopic speed adjustment

0-255

调节频闪速度

address code state, multimachine connection, without control table, which can realize the master-slave
online features, operation of a device, the rest in address d001 state of the host device synchronized wit
h the running program. Through to control if receives the control table, behind the podium display X bec
ome V, the address in the state of equipment can be controlled to control

在地址码状态,多机连接后,若没有接控台,可实现主从联机功能,操作其中的一台设备,
其余的在地址 d001 状态下的设备跟随主机同步运行程序。接通控台后若接收到控台信号,
显示屏的的 X 会变成 V,在地址状态下的设备可受控台控制。

DMX connection DMX

连接

DMX512 is widely used in lamp control, and can control up to 512 channels

On the last luminaire, a terminator is required for the DMX signal line. Solder a 120

Ω

,

1/4W resistor between pin2 and pin3, install it into the 3-pin XLR plug and plug it into the
DMX output port of the last lamp.
Use the XLR signal cable to connect the lamp, one end to the output port of the lamp, and
the other end to the output port of the next lamp. The XLR signal cable can only be used in
series, not parallel. DMX512 signal transmission speed is very fast. Damage to the signal
line, weak welding, poor contact, etc., will affect signal transmission and cause the system
to shut down.
When the power supply of a certain lamp is cut off, the connection of DMX output and
input is bypassed, so that the connection of DMX line can be maintained.
Each lamp needs an address code, which can receive the information sent by the console,
ranging from 0 to 512. The terminal of the system needs to be equipped with a terminator
to reduce signal transmission errors.
DMX address code setting
When using a universal DMX console to control a lamp, please set the start address code

save

5

Now temp

灯珠温度

/

Lamp bead temperature

实测灯珠的当前温度

/Measure

the current temperature of the

lamp beads

Summary of Contents for PS200P

Page 1: ...200W 200W LED Profile Spotlight Professional Version PS200P...

Page 2: ...ratches The lamp must be ged if damaged or distorted by heat If internal access is needed for control service c repair purposes always refer to qualified personnel In all events always unplug the powe...

Page 3: ...230V 1 2M 1 5...

Page 4: ...4 5 Nut for Front Drawtube 5 6 Design Adjustment Tube 6 7 Slot for lris 7 8 Lighting Adjustment Flake 8 9 Screw for Design Adjustment Tube 9 10 Light emitting part 10 11 Handle 11 12 Cooperate with th...

Page 5: ...n Units Quantity 1 Light PCS 1 2 Power coed PCS 1 3 Signal cords PCS 1 4 nstruction manual PCS 1 Purchased separately options Number Description Units Quantity 1 LOGO clamp PCS 1 2 Shrink aperture PCS...

Page 6: ...3000K color rendering index 95 Specialized in imaging lights for theaters theaters TV stations studios and banquet halls 200W 19 26 36 50 LOGO 3000K 95 Use Operation Adjusting Draw out 4Lighting Adju...

Page 7: ...ed Slot 15 then move it forwar the Design Bayonet comes Out then in sert the design flake Tum on the light adjus the Front Drawtube until getting the clearest design the fa sten the Front Drawtube 15...

Page 8: ...200W Edison LED CT 3200K 5600K RA 95 Lens angle 19 26 36 50 Conventional 19 degrees 19 Channel 2CH Control mode DMX512 Master slave Dimming linear dimming Maximum ambient temperature 40 Maximum surfa...

Page 9: ...ess code setting 001 Press the up and down keys to adjust the address code and press the OK key to save 2 R DIMMER 001 LED 255 LED Dimmer255 LED Press the up and down keys to adjust the brightness of...

Page 10: ...pin XLR plug and plug it into the DMX output port of the last lamp Use the XLR signal cable to connect the lamp one end to the output port of the lamp and the other end to the output port of the next...

Page 11: ...gher or lower than the specified value in the instruction manual 3 Confirm that the power cord is not cut or damaged by a sharp blade 4 Be sure to disconnect the power supply when the lamp is not in u...

Page 12: ...y connected 2 The housing lens fixing parts and installation location such as ceiling hanger truss etc cannot be deformed 3 The moving parts of the machinery must not be worn out and cannot rotate unb...

Page 13: ...ition to prevent the circuit contacts from aging due to overheating Please be careful not to use damp linen and never use alcohol or solvents for cleaning If users need any spare parts please purchase...

Reviews: