Level monitoring system
NT 4600
Technical information / Instruction manual
page
Technical Data / Accessories
Technical data
Dimensions
NT 4600, Modbus converter:
300 x 300 x 155 mm (W x H x D)
Dimensions
(Touch panel without
cabinet)
Touch panel
200 x 146 x 34 mm
Panel cutout
192 x 138 mm
Mounting
NT 4600, Modbus converter:
wall mounting
Material
NT 4600, Modbus converter:
steel plate
Ingress protection
NT 4600, Modbus converter:
IP65
Ambient temperature
NT 4600:
0 .. +50°C
Modbusumsetzer:
-25 .. +70°C
Power supply
NT 4600, Modbus converter:
115 V or 230 V 50/
60
Hz (integrated power converter 24
V
DC)
NR 3000:
supplied by Modbus converter
NB 3000/ 4000:
115 V or 230 V AC, connection is made on site
Full detector:
Connection either on NB 3000/ NB 4000 resp. Modbus
converter.In this case the supply voltage must be equal to
NB 3000/ NB 4000 resp. Modbus converter. Alternative it is
possible to connect on site.
Power consumption
NT 4600, Modbus converter:
20 VA
Connected level sensors:
see documentation of the respective sensors
Signal output full detector
Floating contact is required
Terminal box
Intermediate terminals for the wires leading to the silo (mounting e.g. on the silo frame).
Applicable for cables of level (Modbus or 4-20 mA), limit switch, buzzer, reset button
Technical data
Dimensions
200 x 300 x 120 mm (W x H x D), for wall mounting
Material
steel plate
Ingress protection
IP65
Ambient temperature
-25 .. +60°C
Terminal blocks
15 pieces grey, 5 pieces blue, 5 pieces green/yellow; each terminal implements 3 cable inlets
2.5 mm
2
, mounted on top hat rail
Cable glands
6 pieces M20 x 1.5 2 pieces M25 x 1.5
Nivotec
®
1
2
3
4
5
6
7
8
9
10
11
12
NT 4600
gi010417
4