![UWT Nivotec NT 4600 Technical Information/Instruction Manual Download Page 3](http://html1.mh-extra.com/html/uwt/nivotec-nt-4600/nivotec-nt-4600_technical-information-instruction-manual_1066139003.webp)
Level monitoring system
NT 4600
Technical information / Instruction manual
page
Overview
Level monitoring and visualisation via touch panel
- Standardized system up to 15 silos
- Visualisation and operation via 7" touch panel (coloured, 800 x 480 pixel)
- Software language german or english
- Password protected
- Data in percentage, height, volume or weight
- Trend display, data storage
- Evaluation of the analogue 4-20 mA signals of any sensors, as well as Modbus RTU of the UWT-systems
- Different input signals within the same system is possible
- Implementation of full detectors
- Fill control via full alarm signal (Buzzer)
NT 4600 Basis unit
The heart of the NT 4600 is a touch panel, which runs
the visualisation software. All fill level control and display
functions can be operated via the touch panel. Access is
password protected. The electromechanical lead system can
be started by the visualisation software.
Integration of full detector
incl. alarm "silo full"
- Buzzer with reset button (supplied loose,
for outdoor mounting)
- One unit for all connected silos
- Alarm happens, if one of the silos gets full
- Reset of the alarm
- Provided for mounting directly on the silo
Modbus converter
- For connection of 4-20 mA/ 2-wire sensors and full detectors
- On each converter up to 4 sensors and 4 full detectors can
be connected
- Provided for mounting directly on the silo
NT 4600
Buzzer
Reset
button
Modbus converter
e.g
NR 3000
Full detector
M
od
b
us
R
TU
NB 3000/
NB 4000
Modbus RTU
Modbus RTU
4-20
m
A
Full detector
Connection of
further Modbus
converters
Connection of
further
NB 3000/ NB 4000
Basis unit
Alarm "Silo full"
Nivotec
®
1
2
3
4
5
6
7
8
9
10
11
12
NT 4600
gi010417
3