GALILEO 2 (G2) USER MANUAL
2 .6 .2
CNS O
2
=75%
The G2 tracks your oxygen uptake via
the CNS O
2
clock. If the calculated value
of CNS O
2
reaches 75%, this warning
becomes active.
2 .6 .3
No stop time = 2 min
If you wish to avoid unintentionally
performing a decompression dive, the G2
can activate a warning when the no-stop
time reaches 2 minutes. This applies to
current selected MB level no-stop time (see
chapter:
Diving with MB levels,
for more
information on MB level diving). It gives you
the opportunity to start ascending before
incurring a decompression stop or a level
stop obligation.
2 .6 .4
Entering deco
The G2 can activate a warning when
the first mandatory decompression stop
appears. This alerts you to the fact that a
direct ascent to the surface is no longer
possible.
2 .6 .5
Maximum dive time warning
The value can be selected from 5 to 995
minutes in 1-minute increments.