BioDoc-It and VisiDoc-It Imaging Systems 

 

Set-up Instructions 

 

Components 

 

ƒ

 

Camera with zoom lens, bracket, filter, cables 

ƒ

 

BioDoc-It  darkroom or VisiDoc-It hood or stand 

ƒ

 

USB storage device, 1 GB (minimum) 

ƒ

 

Transilluminator (may be ordered separately) 

 
WARNING: DO NOT ATTEMPT TO CONNECT ANY WIRING WHILE THE 
EQUIPMENT IS CONNECTED TO ANY POWER SUPPLY 
 
CAUTION 

Do not install the system in places with high moisture, dust, or high temperature. Do not use any oil or 
petroleum based cleaner for the cabinet. Use only mild soap or detergent solution for cleaning. Ensure that 
the system is turned OFF during cleaning. Keep the equipment away from motors or other large magnetic 
equipment apparatus.   
 
 

Installing the Filter  

Systems include a 50mm sq EtBr filter. The filter is pre-installed in the VisiDoc-It hood at the UVP factory.  
 
To install the 50mm sq Ethidium Bromide (EtBr) filter in the BioDoc-It: 
 

ƒ

 

Carefully remove the filter from the protective 
plastic case, holding the filter at the edges to 
prevent fingerprints.  

ƒ

 

The filter tray is located under the camera bracket 
on the right side top of the darkroom. Slide the 
tray open.  

ƒ

 

Place the filter inside the filter tray so that the text 
on the edge of the filter is positioned so the letters 
are right side up when facing you.   

 

 
Additional filters are available. Refer to Accessories for ordering information. 

 
 

Summary of Contents for BioDoc-It

Page 1: ...Products Ltd 2066 W 11th Street Unit 1 Trinity Hall Farm Estate Upland CA 91786 Nuffield Road Cambridge CB4 1TG UK Phone 800 452 6788 909 946 3197 Phone 44 0 1223 420022 Fax 909 946 3597 Fax 44 0 1223...

Page 2: ...transilluminator in the lab Configurations include a compact hood or camera stand The compact hood fits on top of UVP s High Performance and Benchtop Transilluminators The VisiDoc It System is simila...

Page 3: ...efer to the packing slip and pictured components for parts included with the system VisiDoc It with Hood Transilluminator check the packing slip to determine if the system includes a transilluminator...

Page 4: ...ransilluminator with UV Blocking Cover check the packing slip to determine if the system includes a transilluminator FluorCam 210 Camera with Lens Kit EtBr Filter is Mounted under the Lens 8 LCD Touch...

Page 5: ...front 4 in the back USB storage device capacity 1GB minimum Software TS software Ethidium Bromide Filter EtBr The Ethidium Bromide EtBr Filter 50mm sq UV blocking band pass interference filter blocks...

Page 6: ...hs and high low intensities or the high end FirstLight transilluminator Note For UV protection there is a 10 minute timer installed in the BioDoc It system The timer shuts off the transilluminator aft...

Page 7: ...aviolet transilluminator The converter plate is specially coated to convert the 302nm UV output to white light rather than using a separate white light box The Visi Blue Converter Plate converts UV to...

Page 8: ...m is turned OFF during cleaning Keep the equipment away from motors or other large magnetic equipment apparatus Installing the Filter Systems include a 50mm sq EtBr filter The filter is pre installed...

Page 9: ...nly fit one way Using the four thumb screws provided secure the bracket to the base Slide the camera and lens assembly into the camera bracket Slide the lens through the center hole in the gasket The...

Page 10: ...her end into a UBS port on back of the darkroom Connect the jumper cord from the darkroom to the transilluminator Connect the main power cord from the back of the darkroom to a surge protector power o...

Page 11: ...diopter will only fit one way Using the four thumb screws provided secure the bracket to the base Slide the camera and lens assembly into the camera bracket Slide the lens through the center hole in...

Page 12: ...nect the power cord from the transilluminator to a surge protector power outlet Connect the main power cord from the back of the processor to a surge protector power outlet Printer Set up The thermal...

Page 13: ...er Using the System Powering Up the System In the BioDoc It Power up the system by pushing once on the MAIN POWER button located on the right side of the unit All internal components will now have pow...

Page 14: ...desired angle Turn each knob clockwise to tighten Operating the TS Software The system will go through the boot up process When ready the LCD will display the TS software screen similar to the one be...

Page 15: ...any exposure to UV Using the Gel Viewing Window in the BioDoc It The Gel Viewer has a pressure sensitive clasp Press firmly to open the viewer The glass is UV blocking while providing a clear view to...

Page 16: ...01 Fluorescent Standard Step Tablet 33 0014 02 Doc It LS Analysis Software 97 0185 02 Spectacles UV Blocking UVC 303 98 0002 01 Goggles UV Blocking UVC 503 98 0002 02 Faceshield UV Blocking UVC 803 9...

Page 17: ...r copy of Windows please contact your system administrator for assistance If an error message appears repetitively and your system administrator does not recognize it as a Microsoft Windows error cont...

Page 18: ...rument or part thereof that has been subject to accident negligence alteration abuse or misuse by the end user Moreover UVP makes no warranties whatsoever with respect to parts not supplied by UVP or...

Reviews: