BioDoc-It and VisiDoc-It Imaging Systems 

 

 

Printer 

 

UV/White Converter Plate  

Optional Equipment 

 
Refer to the ordering information section of this manual for 
optional equipment part numbers. 

 

Thermal Printer 

The thermal printer provides archive quality, 256 grayscale 
prints, and five optional cost-effective print sizes. 
 

 

Converter Plates 

The 

UV/White Converter Plate

 allows imaging of non-

fluorescent stained media with an ultraviolet transilluminator. 
The converter plate is specially coated to convert the 302nm 
UV output to white light, rather than using a separate white 
light box.  
 
The 

Visi-Blue Converter Plate

 converts UV to 460-470nm 

designed for use with blue excitation samples and SYBR 
green, SYPRO orange and GFP stains.   
 

 

Transilluminators 

If the system does not include a transilluminator (check the packing slip), contact UVP for ordering 
information or go to UVP’s web site at 

www.uvp.com

. A large selection of transilluminators is available 

from UVP. These units include compact 8-watt models to our high performance FirstLight 
Transilluminator.  
 

 

Summary of Contents for BioDoc-It

Page 1: ...Products Ltd 2066 W 11th Street Unit 1 Trinity Hall Farm Estate Upland CA 91786 Nuffield Road Cambridge CB4 1TG UK Phone 800 452 6788 909 946 3197 Phone 44 0 1223 420022 Fax 909 946 3597 Fax 44 0 1223...

Page 2: ...transilluminator in the lab Configurations include a compact hood or camera stand The compact hood fits on top of UVP s High Performance and Benchtop Transilluminators The VisiDoc It System is simila...

Page 3: ...efer to the packing slip and pictured components for parts included with the system VisiDoc It with Hood Transilluminator check the packing slip to determine if the system includes a transilluminator...

Page 4: ...ransilluminator with UV Blocking Cover check the packing slip to determine if the system includes a transilluminator FluorCam 210 Camera with Lens Kit EtBr Filter is Mounted under the Lens 8 LCD Touch...

Page 5: ...front 4 in the back USB storage device capacity 1GB minimum Software TS software Ethidium Bromide Filter EtBr The Ethidium Bromide EtBr Filter 50mm sq UV blocking band pass interference filter blocks...

Page 6: ...hs and high low intensities or the high end FirstLight transilluminator Note For UV protection there is a 10 minute timer installed in the BioDoc It system The timer shuts off the transilluminator aft...

Page 7: ...aviolet transilluminator The converter plate is specially coated to convert the 302nm UV output to white light rather than using a separate white light box The Visi Blue Converter Plate converts UV to...

Page 8: ...m is turned OFF during cleaning Keep the equipment away from motors or other large magnetic equipment apparatus Installing the Filter Systems include a 50mm sq EtBr filter The filter is pre installed...

Page 9: ...nly fit one way Using the four thumb screws provided secure the bracket to the base Slide the camera and lens assembly into the camera bracket Slide the lens through the center hole in the gasket The...

Page 10: ...her end into a UBS port on back of the darkroom Connect the jumper cord from the darkroom to the transilluminator Connect the main power cord from the back of the darkroom to a surge protector power o...

Page 11: ...diopter will only fit one way Using the four thumb screws provided secure the bracket to the base Slide the camera and lens assembly into the camera bracket Slide the lens through the center hole in...

Page 12: ...nect the power cord from the transilluminator to a surge protector power outlet Connect the main power cord from the back of the processor to a surge protector power outlet Printer Set up The thermal...

Page 13: ...er Using the System Powering Up the System In the BioDoc It Power up the system by pushing once on the MAIN POWER button located on the right side of the unit All internal components will now have pow...

Page 14: ...desired angle Turn each knob clockwise to tighten Operating the TS Software The system will go through the boot up process When ready the LCD will display the TS software screen similar to the one be...

Page 15: ...any exposure to UV Using the Gel Viewing Window in the BioDoc It The Gel Viewer has a pressure sensitive clasp Press firmly to open the viewer The glass is UV blocking while providing a clear view to...

Page 16: ...01 Fluorescent Standard Step Tablet 33 0014 02 Doc It LS Analysis Software 97 0185 02 Spectacles UV Blocking UVC 303 98 0002 01 Goggles UV Blocking UVC 503 98 0002 02 Faceshield UV Blocking UVC 803 9...

Page 17: ...r copy of Windows please contact your system administrator for assistance If an error message appears repetitively and your system administrator does not recognize it as a Microsoft Windows error cont...

Page 18: ...rument or part thereof that has been subject to accident negligence alteration abuse or misuse by the end user Moreover UVP makes no warranties whatsoever with respect to parts not supplied by UVP or...

Reviews: