Operating Manual 

Electronic Power Supply 

EVG UVT 2x 100-200 W  1.2-2.1 A 
EVG UVT 2x 150-320 W  1.5-2.1 A 
EVG UVT 2x 150-320 W  1.8-2.9 A 

Summary of Contents for EVG UVT 2x 100-200 W

Page 1: ...ik Speziallampen GmbH Gewerbegebiet Ost 6 98704 Wolfsberg Stand 07 07 2016 Operating Manual Electronic Power Supply EVG UVT 2x 100 200 W 1 2 2 1 A EVG UVT 2x 150 320 W 1 5 2 1 A EVG UVT 2x 150 320 W 1...

Page 2: ...written permission of the UV Technik Speziallampen GmbH If any part of this user s manual is reproduced stored in a retrieval system or transmitted in any form or by any means without obtaining the p...

Page 3: ...ty and liability 7 Organizational measures 7 Informal safety measures 8 Danger due to electricity 8 Service maintenance remedying faults 8 3 Transport storage delivery 9 4 Order data for equipment 9 E...

Page 4: ...an immediately threatening danger If it is not avoided death or very severe injuries damage to health will result Damage to property is possible The signal word marks a danger with medium risk or dan...

Page 5: ...e failure of one lamp do not provoke the breakdown of the second lamp The permanent operation with only one lamp must be avoided if the allowed minimal input power will be undercut The EVG UVT contain...

Page 6: ...ons Appropriate use EVG UVT is a microprocessor based electronic power supply for UV low pressure lamps Any other use or use above and beyond these terms is defined as inappropriate and is thus danger...

Page 7: ...ology The equipment may only be used under the following conditions it is used for the purpose for which it was constructed which the equipment complies with all safety technology requirements HAZARDO...

Page 8: ...observed HAZARDOUS ELECTRICAL VOLTAGE There is a danger causes by direct or indirect contact with electricity The electrical components of the EVG UVT must be inspected regularly equipment components...

Page 9: ...pment Order equipment from UV Technik Speziallampen GmbH Gewerbegebiet Ost 6 98704 Wolfsberg OT W mbach Tel 0049 36785 520 0 Fax 0049 36785 520 21 E Mail info uvtechnik com Equipment Description Artic...

Page 10: ...normal operation on off on system lamp ballast ok start condition not fulfilled off steady blink steady blink ballast is waiting for start mains under or overvoltage start at over temperature no lamp...

Page 11: ...ay contacts terminal 6 8 9 11 1 changer maximal load 5 A 250 V AC 5 A 24 V DC ohmic load recommended minimal load 12 V DC 10 mA remote input terminal 1 2 10 230 V AC DC galvanically isolated to be use...

Page 12: ...igned for installation in electrical cabinets IP protection class IP20 size of housing w x d x h borehole spacing 240 mm 250 x 105 x 60 mm 2x 100 200W 250 x 150 x 60 mm 2x 150 320W mounting position v...

Page 13: ...ndatory operating manual EVG UVT 200 480W subject to change without notice page 13 of 17 8 Technical documentation Terminal diagram Dimensional drawing depth EVG UVT 2x 100 200W 105 mm depth EVG UVT 2...

Page 14: ...connections to the lamp may not be disconnected during operation By no means install additonal components into the lamp supply cable such as relays switches ignitors or capacitors The number of the cl...

Page 15: ...omponent see chart We use only premium quality capacitors of the highest temperature stability In compliance with the installation instructions as well as the maximum housing temperature a lifetime of...

Page 16: ...Besides the usual operation LEDs the EVG UVT are equipped with a potential free signal output per chanel lamp which notifies the proper function of the unit This output is a relay that switches once...

Page 17: ...to check the complete system according to the relevant rules If several ballasts build in a unit generally additional measures can be necessary to eliminate interferences Beside the observance of the...