prevent damage (see Draining Instructions page 31). The water temperature
range is 1–40°C (34–104°F). In extreme conditions with both low air and water
temperatures, a Thermal Abatement Kit R400074 may be necessary.
Energy Requirements:
There are two standard operating voltages for the Hallett 15xs unit. The unit may
be 115Vac or 100-240 Vac and draws 175W. Please refer to the power input
label located near the power cord entry of the unit. See Figure 1B. For
convenience the front cover of the manual should also contain model number
and operating voltage.
Safety Information
WARNING
:
Potential Shock Hazard
Use only a grounded electrical outlet when connecting the unit to a
power source. If you do not know whether the outlet is grounded,
check with a qualified electrician. If an extension cord is necessary,
the cord should contain a ground and be rated for the same
amperage as the unit or combined units. The piping connected to
the Hallett unit must also be properly grounded. Do not plug in unit if
water is present on the unit.
WARNING: Ultraviolet Light Hazard
The lamps in the unit emit ultraviolet (UV) light that can cause
permanent damage to the skin & eyes.
Never look at the lamp
when it is operating.
Do not plug the unit in unless it is properly
secured to a wall (see Installation Instructions) and the front panel
and ballast enclosure door are secure. Do not open the front panel
or perform any service unless the unit has been unplugged. Never
look into the unit or place any exposed skin into the illuminated
areas when it is operating. Do not operate a unit that has been
damaged or missing any components or safety devices.
Note that service to the unit does not require the removal of the side
aluminum panels or aluminum endplates and they must remain
assembled. The Hallett unit is not intended for use by young children
or infirm persons without supervision. Young children should be
supervised to ensure that they do not play with the Hallett unit.
Parts Included
Hallett UV system complete with integral wall brackets (1)
Instruction manual (1)
Product & warranty registration card (1)
Power cord (1) (located within packaging)
Stainless flexible hoses (2) per system (hoses located within
packaging)
Ultraviolet lamps (2) – installed within the unit
Automatic shutoff solenoid valve