Models 

INSTALLATION & OPERATIONS MANUAL 

System

 tested and

 certified by

IAPMO against: 

NSF/ANSI Standard 55 Class A 

NSF/ANSI 61 

NSF/ANSI 372 

CSA-B483.1

UVDynamics 

a Castle Circuits Inc. Business Group 

315 Neptune Crescent 

London, Ontario 

Canada, N6M 1A9 

  1.800.667.4629

 

 1.519.452.1701

 

[email protected] 

WWW.UVDYNAMICS.COM 

© 

COPYRIGHT 201

9

 

 UVDynamics – a Castle Circuits Inc. Business Group 

 All RIGHTS RESERVED

NSF/ANSI 55 

Drinking Water 

8.40C  8gpm 

11.40C  11gpm 
14.40C  14gpm 
20.40C  20gpm 

Summary of Contents for 11.40C

Page 1: ...SA B483 1 UVDynamics a Castle Circuits Inc Business Group 315 Neptune Crescent London Ontario Canada N6M 1A9 1 800 667 4629 1 519 452 1701 support uvdynamics com WWW UVDYNAMICS COM COPYRIGHT 2019 UVDynamics a Castle Circuits Inc Business Group All RIGHTS RESERVED NSF ANSI 55 Drinking Water 8 40C 8gpm 11 40C 11gpm 14 40C 14gpm 20 40C 20gpm ...

Page 2: ...tem failure is resolved This installation and operating manual is to be kept with UV system APPLICATION OVERVIEW UVDynamics UV disinfection systems certified to NSF ANSI standard 55 are suitable for use on waters which are known to be contaminated This product uses a proprietary extended cold spot lamp design along with an active temperature controlled cold spot cooling fan resulting in improved l...

Page 3: ...ar plastic threads or fittings SOLENOID VALVE INSTALLATION On vertically mounted systems a solenoid valve can be directly mounted to the inlet port In all other mounting configurations the solenoid valve should be isolated by 12 30cm of piping on either port of horizontally mounted disinfection chambers and the output port of vertically mounted chambers Mounting of the solenoid valve directly to t...

Page 4: ... mj cm2 Diagnostic Display Pushing the timer reset button on the UV power source initiates the diagnostic display and sensor self test function of the system In sequence the display will output the parameter followed by the parameter value lr Lamp life remaining weeks ul UV level tf Disinfection Chamber temperature F0 tc Disinfection Chamber temperature C0 fn Cold Spot FanTM status 1 on 0 off at A...

Page 5: ...uartz sleeve as it is easily broken Carefully slide the UV lamp out of the quartz sleeve and discard according to local disposal regulations Remove the quartz sleeve by loosening the gland nut s and carefully extracting it from unit Caution The quartz sleeve is fragile and is easily chipped or broken use care when removing or installing Clean the quartz sleeve with a vinegar solution or any readil...

Page 6: ...O Ring Part 400286 IEC Power Cord Part 400114 all models ColdSpot Fan TM Part 400290 all models Outlet Port Disinfection Chamber Model 8 40C Part 400304 Mounting bracket Part 400108 Inlet Port UV Sensor Probe Part 400285 all models UV Sensor O Ring Part 400289 COMPONENT IDENTIFIIER Model 8 40C 5 Flow regulator insert Part 400159 Retainer 0 Ring Part 400286 COPYRIGHT 2019 UVDynamics a Castle Circui...

Page 7: ...40C 240V Part 400497 IEC Power Cord Part 400114 120V O Ring Part 400286 Outlet Port Disinfection Chamber Model 11 40C Part 400666 Model 14 40C Part 400310 Model 20 40C Part 400612 Inlet Port O Ring Part 400286 Glandnut Part 400287 UV Sensor Probe Part 400285 UV Sensor O Ring Part 400289 ColdSpot Fan TM Part 400290 Mounting bracket Part 400108 COMPONENT IDENTIFIIER Model 11 40C 14 40C 20 40C 6 Flow...

Page 8: ...sponsible for water damage When the disinfection system can only be located where water damage is a possibility the installation of an automatic leak detector shut off device is highly recommended OPTIONAL additional pre treatment as required 5 micron sediment filter minimum required pre treatment UV detector probe UV Disinfection Chamber IEC power cord GFI protected outlet Inlet UV Power Source 7...

Page 9: ...be UV Power Source UV Disinfection Chamber Disinfected water to all taps and appliances IEC power cord Select a disinfection system mounting location where a potential leak will not cause water damage UVDynamics is not responsible for water damage When the disinfection system can only be located where water damage is a possibility the installation of a automatic leak detector shut off device is hi...

Page 10: ...n a pail or other suitable receptacle to contain the purge water and slowly partially open the inlet isolation valve to purge the hot water from the disinfection chamber If you chose to purge the hot water from the disinfection chamber by placing the solenoid valve in the by pass mode and using a tap on the plumbing system you will be required to disinfect the plumbing system as described in this ...

Page 11: ...ynamics have any liability for liquidated damages for collateral consequential or special damages or for loss of profits or for actual losses or for loss of production or progress of construction regardless of the cause of such damages or losses In any event UV Dynamics aggregate total liability shall not exceed the specific product purchase price The purchaser agrees to indemnify and hold harmles...