MASTER plastering machine
10
2.6 Other
indications
x
It is recommended to use only original spare parts and fittings.
x
Any modification on the original equipment is not admissible.
3 Starting
3.1 Machine
installation
The MASTER must be placed over a flat surface, and must be fastened through the two brakes
on the wheels. The compressor connection points and the starter engines are connected through the
current bases on the circuit board. It is impossible to get confused, as connectors have different colours
and length.
The feed auger switches and the main switch shall be placed on the “0” position. The additional
cleaning connection and the evacuation keys on the water taps must be closed. We shall also check if
the material gate is closed.
3.2
Tuning of the current supply
Use only a 5 poles network cable, with building quality section 5*2’5 mm
2
and 1 KV. To
avoid any voltage losses, the network cable must always be completely unwound!
WARNING!
3.3
Tuning of the water supply
The folds and high pressure resistant water hose must be completely laid out, and must have a
minimum internal diameter of 3/4”. It has to be connected to the appropriate water tap and has to be
released of any air. The water manometer hand must indicate a minimum of 3’5 bars, which is
obtained by installing a pump, already incorporated, which increases water pressure between the
network and the machine.
3.4
Placement and lubrication of the product hose
The MASTER comes already with an original manufacturer’s product hose and its
corresponding couplings. The hose distance must be as short as possible. It is recommended to
moisten or lubricate it internally, to avoid obstructions. To this effect, a coupling for the hose cleaning
connection is connected to the machine, which fills the hose with water and throws it out at the end.
3.5
Air hose and spraying gun connection
The 3/8” air hose is spread out to protect is against pressure and folds, and parallel to the
product hose, to be finally connected to the machine water outlet. When doing this, we must make sure
that the compressor's hose has been connected to the air pressure switch and its socket to the
corresponding network power point on the circuit board. At the other end of the air hose, the spraying
gun is connected and the air diffuser adjusted (the product nozzle diameter corresponds to the air
diffuser distance on the spraying gun).