5
This appliance is a gas-fired direct vent hot water boiler with
cast aluminum boiler sections. A revolutionary cast aluminum
heat exchanger means better heat transfer and thermal storage
than similarly sized cast iron boilers, which results in higher
efficiency. The heating system water absorbs large amounts of
heat from the cast aluminum heat exchanger, cooling the flue
gases and causing condensation. Sealed combustion, premix
gas burner, and low flame temperature means drastically
reduced CO and NOx emissions, which contribute to a cleaner
and healthier environment.
This appliance, unlike normal residential atmospheric and
induced draft units, takes its combustion air directly from
the outdoors (sealed combustion) and does not compete with
building occupants for fresh air. Sealed combustion (also
known as “direct vent”) is the safest and best way to obtain
plenty of clean combustion air. The induced draft fan draws
in the outside combustion air, then takes the cooler flue gases
from the boiler unit and provides a positive removal of the flue
gases from the building through inexpensive and readily avail-
able PVC and CPVC pipes.
INTRODUCTION
Figure 1
Summary of Contents for UB90-100
Page 15: ...15 Near Boiler Piping Figure 2 Single Zone Boiler Piping ...
Page 16: ...16 Figure 3 Multi zone Boiler Piping With Zone Valves Near Boiler Piping ...
Page 19: ...19 Figure 6 Diaphragm Type Expansion Tank Piping Near Boiler Piping ...
Page 20: ...20 Figure 7 Conventional closed type Expansion Tank Piping Near Boiler Piping ...
Page 27: ...27 Combustion Air and Vent Pipe Figure 11 Combustion Air and Vent Piping ...
Page 32: ...32 Electrical Wiring Figure 13 Field Wiring Connections ...
Page 53: ...53 DETAILED SEQUENCE OF OPERATION ...
Page 57: ...57 TROUBLESHOOTING CHART 2 TROUBLESHOOTING ...
Page 58: ...58 TROUBLESHOOTING CHART 3 TROUBLESHOOTING ...