Low Power WiFi Module User Manual V1.3
http://www.tcp232.net
Jinan USR IOT Technology Limited.
Page 38 of 59
Query Operation
AT+MID<CR>
+ok=<module_id><CR>< LF ><CR>< LF >
Parameters:
module_id: Module ID information;
HF-LPB;
Notes: User can set this parameter through AT+WRMID.
4.2.2.6. AT+VER
Function: Query module software version information;
Format:
Query Operation
AT+VER<CR>
+ok=<ver><CR>< LF ><CR>< LF >
Parameters:
ver: Module software version information;
4.2.2.7. AT+RELD
Function: module restore to factory default setting;
Format:
Set Operation
AT+ RELD<CR>
+ok=rebooting…<CR>< LF ><CR>< LF >
When operate this command, module will restore to factory default setting and reboot.
4.2.2.8. AT+Z
Function: Re-start module;
Format:
AT+ Z<CR>
4.2.2.9. AT+H
Function: Help;
Format:
Query Operation
AT+H<CR>
+ok=<command help><CR>< LF ><CR>< LF >
Parameters:
command help: command introduction;
4.2.2.10. AT+CFGRD
Function: Batch Read User Configure Parameters;
Format:
Query Operation
AT+CFGRD<CR>