6. STARTING THE TREATMENT SESSION 

1.

 

Verify the main switch (back side of the console) is in OFF position. 

2.

 

Connect the DC power adapter cable to the DC adapter socket (located under the Main 
Switch). 

3.

 

Connect the power cord to the electrical outlet. 

4.

 

Put on the abdominal belt, following the instructions in Section 3.3 above and get into a 
comfortable seated, reclining, or lying position from where you can easily reach the console 
controls. 

5.

 

Connect  the  belt  to  the  desktop  device  and  make  sure  that  the  hoses  are  properly 
connected (3.4). 

6.

 

Turn on the Main Switch to the ON position. 

7.

 

Press the Start/Pause button. - Treatment begins. 

7. ENDING THE TREATMENT SESSION 

When  your  treatment  time  is  complete,  MOWOOT  II  system  will  stop.  If  you  need  to  pause  the 
massage during the treatment session, press Start/Pause button. If you need to definitely stop the 
treatment  before  massage  is  finished,  press  Stop  button.  At  the  end  of  treatment,  turn  OFF  the 
console using the Main Switch. 
 

NOTE - When immediate abdominal belt deflation is necessary, disconnect the belt from the console to 
immediately deflate the air pressure in the belt actuators. 

8. MAINTENANCE & STORAGE 

8.1 Cleaning 

Gently wipe the external surfaces using a soft cloth, warm water and a mild detergent. Wipe with 
clear water. Wipe dry using a soft towel only. When dry, the external surfaces may be wiped down 
with alcohol. When using alcohol, wear gloves and work in a well-ventilated area. Allow the device 
to air dry completely before use. 
 

8.2 Console Cautions

 

Disconnect  the  console  from  electrical  outlet  before  cleaning.  Let  it  dry  completely  before 
reconnecting it to the electrical outlet. o not allow any moisture or liquids to enter the console. 
 

8.3 Belt Cautions 

Never submerge the belt in liquid. Do not hand or machine wash. Do not use bleach. Do not wring, 
iron, tumble, do not dry mechanically or dry with dry heat. Do not allow liquid to get into the air 
inlets. 
 

8.4 Storage & Transportation 

Keep  the  device  away  from  direct  sunlight,  store  in  a  dry,  shaded  place,  do  not  twist  or  fold  the 
connector tubes and store the power cord lightly wrapped and secured. 
 
The components of the MOWOOT II system should only be transported in their original packaging. 

Summary of Contents for MOWOOT II

Page 1: ...MOWOOT II usMIMA S L User Manual Version 10 Page 1 20 User Manual ...

Page 2: ...OWOOT II usMIMA S L User Manual Version 10 Page 2 20 usMIMA S L Avinguda Cornellà 142 08950 Esplugues de Llobregat Barcelona Spain B66400409 Tel 93 510 66 53 Mail info mowoot com Web www mowoot com 2797 ...

Page 3: ...LABELS 6 1 INTRODUCTION THE MOWOOT II SYSTEM 7 2 COMPONENTS OF THE MOWOOT II SYSTEM 7 2 1 Console and Accessories 7 2 2 Exoperistaltic Abdominal Belt 8 3 SETTING UP THE SYSTEM 8 3 1 Set up the Console 8 3 2 Put on Clothing that Covers the Treated Area 8 3 3 Put on the Abdominal Belt 8 3 4 Attach the Belt to the Console 9 3 5 Treatment Positions 9 4 USE OF THE DEVICE 9 4 1 The Console Controls 10 ...

Page 4: ...1 8 4 Storage Transportation 11 9 TROUBLESHOOTING 12 10 ASSISTANCE 12 11 SPARE PARTS 12 12 DISPOSALS 13 13 WARRANTY CONTACT INFORMATION 13 _Manufacturer Warranty 13 _Certificate of Warranty 13 _Warranty Conditions 13 1 Data and Documentation 13 2 Exclusions 14 _Geographical Scope 14 _Pieces 14 _Cancellation of Warranty 15 _Data Protection 15 ANNEX I CLASSIFICATIONS 15 ANEXO II ESPECIFICACIONES TÉC...

Page 5: ... persons simultaneously both by patients at home and by medical practitioners in clinics CONTRAINDICACIONS Pregnancy acute active abdominal tumour disease unstable vertebral fracture acute inflammatory processes in the abdomen an intra abdominal implant e g pump catheter SARS implant when located between the colon and the pneumatically operated actuators of the MOWOOT II belt abdominal stoma cereb...

Page 6: ...ile in use place the console on horizontal firm surface Do not cover the console LABELS Symbol Description Location 2797 CE label showing compliance with European Directive 2007 47 EC amending Directive 93 42 EEC concerning medical devices Desktop Device Belt Packaging Read Instructions before use Desktop Device Packaging Read Instructions before use Desktop Device Packaging Level of protection ty...

Page 7: ...s applicable to medical devices following the highest quality standard and thus guaranteeing the maximum safety MOWOOT II does not interfere neither is affected by other electronic devices 2 COMPONENTS OF THE MOWOOT II SYSTEM 2 1 Console and Accessories Component Illustration The console supplies air to the exoperistaltic belt There are two air outlets on the front of the unit The console can oper...

Page 8: ... Large Size L Grey border perimeter 950 1150 mm Extra Large Size XL Black border perimeter 1100 1300 mm 3 SETTING UP THE SYSTEM Make sure to be able to reach the MOWOOT II System at any time during treatment 3 1 Set up the Console Place the console on a flat stable surface from where it will not slip or fall Plug the DC power adapter cable into the DC adapter socket on the console and then plug th...

Page 9: ...To remove belt connector squeeze the release buttons at either side of the connector and pull out the connector b If using only one abdominal belt plug the blocking connector into the unused air outlet If it is left open air will escape the console will stop working the Status LED will turn on in red and the alarm will beep 3 5 Treatment Positions Always make sure the controls on the console and t...

Page 10: ...nsole located at the back side of the console at lower right DC Adapter Socket Used for connecting the DC power adapter located under the Main Switch 5 SETTING TREATMENT FREQUENCY AND TIME Set the Time Knob to the massage duration you want We recommend a daily use time of 20 minutes The minimum treatment time setting is 1 minute The maximum treatment time setting is 20 minutes It can be used at an...

Page 11: ... NOTE When immediate abdominal belt deflation is necessary disconnect the belt from the console to immediately deflate the air pressure in the belt actuators 8 MAINTENANCE STORAGE 8 1 Cleaning Gently wipe the external surfaces using a soft cloth warm water and a mild detergent Wipe with clear water Wipe dry using a soft towel only When dry the external surfaces may be wiped down with alcohol When ...

Page 12: ...inks twists and folds The console stops working the Status LED turns on in red and the buzzer beeps 1 Abdominal belt is not connected properly to console 2 Additional plug is not inserted into unused air outlet 3 Always plug the unused air outlet with the prong plug provided with the console If all connections are OK and problem persists contact usMIMA S L Irregular noise 1 Transferring of vibrati...

Page 13: ...If during this period of validity of the warranty the Device presents any defect attributable to the manufacturing process due to materials and or labour the consumer must inform usMIMA within 2 months after being aware of such defect and may choose to require the replacement of the Device The guarantee of the device subject to guarantee will be free for the consumer and user Such gratuity shall c...

Page 14: ...on of any accessory or decorative surface of the device 4 Damage or damage to any unit or device in which the serial number has been erased modified withdrawn or manipulated 5 Damage caused by causes beyond the design or manufacture of the Device e g power failure 6 Periodic reviews maintenance and repair or replacement of parts due to normal wear and tear of the Device 7 Indirect damages and loss...

Page 15: ...Standard 93 42 EEC Section IX Rule 9 The protection against electric shock is Class A and DC Degree of protection against electric shock of type BF Clasif CEI EN 60601 1 Degree of IP 21 EC 2797 The device is not protected against water penetration The device is not subject to sterilization Continuous operation device The device is not suitable for outdoor use ANEXO II ESPECIFICACIONES TÉCNICAS Tre...

Page 16: ...ed separation distances between portable and mobile RF communication equipment and the desktop device system 3 Wireless communications equipment such as wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance d 3 3 m way from the system Rated Maximum Output Power of Transmitter W Separat...

Page 17: ...r of the MOWOOT II should assure that it is used in such an environment MOWOOT II is intended for use in the electromagnetic environment specified below The customer or the user of the MOWOOT II should assure that it is used in such an environment Immunity Test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air...

Page 18: ... of transmitter W Separation distance according to frequency of transmitter 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 1 2 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable t...

Page 19: ...ths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by abso...

Page 20: ...OWOOT II usMIMA S L User Manual Version 10 Page 20 20 usMIMA S L Avinguda Cornellà 142 08950 Esplugues de Llobregat Barcelona Spain B66400409 Tel 93 510 66 53 Mail info mowoot com Web www mowoot com 2797 ...

Reviews: