38000-L01-001_Rev_J_SugarCUBE_Manual
22
Normal Operation
Unit Status
Operation
On/Stby AND
Intensity Adjustment
buttons enabled.
(Unit in Standby
Mode)
•
One Intensity Indicator LED is active.
•
Power Indicator LED pulses once per second.
•
Fans will be OFF.
On/Stby AND
Intensity Adjustment
buttons enabled.
(Unit in Standby
Mode)
•
One Intensity Indicator LED is active.
•
Power Indicator LED pulses twice per second.
•
Fans will be OFF.
LED On
•
One Intensity Indicator LED is active.
•
Power Indicator LED is continuously illuminated.
•
LED cooling fan will be ON.
•
Power supply cooling fan will be either on or off.
Overheat Condition
•
One Intensity Indicator LED is active.
•
Power Indicator LED pulses rapidly.
•
After the unit cools, the user must toggle
On/Stby button to clear the overheat lockout.
•
Alternatively, the user can toggle the Main
Power switch to clear the overheat lockout.
•
Fans will be off.