![Ushio SugarCube 38000-M03-002 Operating And Owners Manual Download Page 18](http://html1.mh-extra.com/html/ushio/sugarcube-38000-m03-002/sugarcube-38000-m03-002_operating-and-owners-manual_1064214018.webp)
38000-L01-001_Rev_J_SugarCUBE_Manual
18
7.3
Using RS-232 Commands
The
SugarCUBE™
features an RS-232 communications port, which (via
commands) can be used to remotely control all front panel functions.
Additionally, commands exist to provide more precise intensity adjustments as
well as helpful status indicators.
NOTE:
As with Analog Mode and the Relay Control,
associated optional cables and RS232 interface
adapters are available for purchase at
7.3.1
Communications Connection Option 1
1.
Flip the Main Power ON/OFF (I/0) switch to the OFF (0) position.
2.
Using the Blank Communication Cable (P/N 38000-M03-021), connect
the host computer’s RS-232 port to the SugarCUBE’s RS-232 port. Use
the image below for reference.
3.
Flip the Main Power ON/OFF switch to the ON (I) position.
4.
The Power Indicator will flash approximately once per second to
indicate the unit is running and in Standby Mode.
5.
The Intensity Indicators will display the current LED intensity level.
6.
With an appropriate terminal program, computer commands can now
be transmitted to control the unit and query its status. The
communication protocol can be found in
Appendix A
.