7
INSTALLATION
NOTE:
DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation. Refer to:
SHIPPING DAMAGE CLAIM
PROCEDURE
on the inside of this
manual.
WARNING:
RISK OF PERSONAL INJURY
Installation procedures must be
performed by a qualified technician
with full knowledge of all applicable
electrical and plumbing codes.
Failure can result in personal injury
and property damage.
IMPORTANT:
Unit must remain in an upright
position during installation to
prevent damage to the
refrigeration system.
IMPORTANT:
Refrigeration system is air-cooled.
Recommended louvered grills or
equivalent openings front and rear,
each with a minimum size of twice
the surface area of the condenser,
to provide adequate air circulation.
IMPORTANT:
Access is required for the operation
of the drain valve and for
maintenance of the refrigeration unit.
Provide adequate access to the drain
valve and refrigeration unit.
IMPORTANT:
Unit flange must be sealed to the
countertop. Damage caused by leaks
due to improper installation is NOT
covered by warranty.
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective
plastic film, packing materials and accessories from the appliance before
connecting electrical power or otherwise performing any installation
procedure.
Carefully read all instructions in this manual and the
Installation
Instruction Sheet
packed with the appliance before starting any
installation.
Read and understand all labels and diagrams attached to the
appliance.
Carefully account for all components and accessories before
discarding packing materials. Store all accessories in a
convenient place for a later use.
USECO units must remain upright at all times (shipping &
installation) to prevent damage to the condensing unit. If the
unit is accidentally tipped, allow unit to sit upright for at least
24 hours before connecting to electric power.
COMPONENTS
1 ea. PAN RAIL
1-5 ea. PAN ADAPTER BAR(S) (qty differs with unit)
1 ea. DRAIN VALVE
1 ea. DRAIN SCREEN
PREPARATION
Cutout dimensions for tank units and control panels are listed on
the
Installation Instructions
provided with the unit.
Provide at least 1” clearance around the condensing unit chassis.
Countertop must be flat and level before the unit is installed.
After cutout is made, add stiffeners or bottom braces to counter
as required to support unit weight.
IMPORTANT
:
Refrigeration system is air-cooled. Recommend louvered grills
or equivalent opening front and rear, each with a minimum size
of twice surface are of the condenser, to provide adequate air
circulation.
NOTE:
The condenser fan is provided with a fan guard. DO
NOT remove the condenser fan guard.
Provide louvered grills and service access below control panel.
Provide access to the POWER SWITCH and TEMP CONTROL
UNIT located at the front of the condenser.
Verify that provided sealants are applied to the underside of the
top flange prior to setting the unit into the cutout.
After installation, apply a thin bead of food-grade silicone
sealant around the flange to seal it to the counter.
Avoid storing flammable or combustible materials in, on or near
the appliance.