  Unscrew the upper parts of the two wireless water detectors and 

insert a 9V battery in each. 

 

 

 

Only 2 wireless water detectors that are currently to be 
programmed may be put into operation at the same time 
and not all of the detectors used in the house! 

 

  Press and hold the internal button for approx. 2-3 seconds on a 

wireless  water  detector.  The  red  LED  will  then  start  flashing 
approx. once per second. 

  Release the key again. 

  The  wireless  water  detector  is  now  in  programming  mode  for 

approx. 60 seconds. 

  Immediately  afterwards,  press  the  button  for  approx.  2-3 

seconds on another wireless water detector. The red LED will 
then start flashing approx. once per second. 

  Release the key again. 

  The wireless water detector is in programming mode for approx. 

60 seconds. Both radio water detectors automatically program 
each  other into  a  radio  group.  The  programming  process  can 
take up to approx. 60 seconds in total. 

  If  the  programming  was  successful,  the  red  LEDs  on  both 

wireless water detectors light up permanently for 2-3 seconds. 

  If  after  approx.  60  seconds  the  red  LEDs  do  not  light  up 

permanently for 2-3 seconds, the programming procedure was 
not successful and the wireless water detectors return to normal 
mode. 

  In this case the programming procedure must be repeated. 

 

Summary of Contents for FlowTimer+ Detect RF Set

Page 1: ...FlowTimer Detect RF Set Direct water detection with the FlowTimer System Operating manual...

Page 2: ...2020 Print date 26 06 2020 Copyright usetech GmbH This documentation including all its parts is protected by copyright Any use or modification outside the narrow limits of the copyright law without t...

Page 3: ...7 4 System description FlowTimer Detect RF Set 8 4 1 Scope of delivery FlowTimer Detect RF Set 8 5 Installation 9 5 1 Placement of the radio water detectors 9 5 2 Placement of splitter and cables 9 5...

Page 4: ...Table of contents 05 20 FlowTimer Detect RF Set 2 8 Packing transport storage 14 9 Disposal and EC declaration of conformity 15...

Page 5: ...rating instructions must be read and understood 1 1 Explanation of symbols DANGER Warning of an immediate danger Failure to observe this warning may result in death or serious injury WARNING Warns of...

Page 6: ...refers to information in this operating manual or in other documentation Action steps The defined sequence of action steps facilitates the correct and safe use of the system Result Here you will find...

Page 7: ...frequency 868 MHz Permissible ambient temperature 0 C 40 C Dimensions 101 x H 37 mm 2 2 Environmental and climatic conditions splinter Ambient temperature 5 C 40 C Protection class IP20 Installation...

Page 8: ...he installation site of FlowTimer and monitors e g the house filter Additional wireless water sensors can be located up to 25 meters away depending on the environment bathroom kitchen etc whereby each...

Page 9: ...Hub to connect FlowTimer devices to each other It can only be used within an I O connection between FlowTimer and FlowTimer Hub to connect accessories The water sensor is only suitable for electricall...

Page 10: ...description FlowTimer Detect RF Set 4 1 Scope of delivery FlowTimer Detect RF Set Figure 4 1 Scope of delivery FlowTimer Detect RF Set 1 Wireless water detector with 2 m cable and I O connector 2 Rad...

Page 11: ...er than the water sensor to protect the splitter and connectors from water in case of flooding 5 3 Electrical connection Insert the I O connector of the wireless water detector 1 into the FlowTimer I...

Page 12: ...ds Immediately afterwards press the button for approx 2 3 seconds on another wireless water detector The red LED will then start flashing approx once per second Release the key again The wireless wate...

Page 13: ...ess group 5 6 Functional test For the test bridge the three sensor surfaces by placing the wireless water detector 1 connected to the FlowTimer e g on a plate that is slightly filled with water The de...

Page 14: ...alarms acoustically 6 1 2 Restarting the system An alarm reset can only be done via the connected FlowTimer or its supply voltage A further prerequisite for this is that all water detectors are dry a...

Page 15: ...thout any reason disconnect the I O connector of the wireless water detector 1 from the I O connector of the FlowTimer Now check your FlowTimer system according to the instructions of the respective p...

Page 16: ...protected from moisture and dirt in shockproof packaging Avoid exceeding or falling below the permissible bearing temperature Protect electrical connections from damage with protective caps The system...

Page 17: ...cal retail outlet free of charge Disposal in household waste is expressly prohibited according to the Ordinance on Waste Equipment You can return devices received from us free of charge after use by s...

Page 18: ...Disposal and EC declaration of conformity 05 20 FlowTimer Detect RF Set 16...

Reviews: