Inquire the current setting 

NAME= 

 

This command is used to specify a name for the adapter.  
You can specify a friendly name using 0 to 9, A to Z, a to z, space and –, which are all 
valid characters. Note that “first space or -, last space or – isn’t permitted”. The default 
name is “Serial Adapter”. 

(Default) 

Serial 
Adapter 

Default device name 

 

xx….xx 

“xx….xx” is a character string with the length from 2 to 30. 

 

Restore the default settings name=“Serial Adapter”. 

 

Inquire the name of the local adapter. 

ONE= 

 

The master will link with one paired or any nearby slave automatically 

(Default) 

The master will link with any nearby slave automatically. 

 

The master will auto link with the pre-paired slave only. The adapter will not connect with 
other slaves if the pre-paired slave is not online. Multiple pairs within the same space is 
supported.  

 

Inquire the current setting 

PARITY= 

 

This command is used to specify parity bit setting of COM port. 
The command will need 200 ms delay. 

(Default) 

None parity bit 

 

Odd parity 

 

Even parity 

 

Inquire the current setting. 

PIN= 

 

This command is used to specify a PIN. The default PIN is “1234”. Paired adapters 
should have a same PIN. The length must be 4 – 16 alphanumeric characters. 
Notice: SSP (secure simple pairing) is supported which means that the master will not 
need the pin code to link. 
Notice: this function currently only works with Windows versions prior to Windows 8.1 

(Default) 

1234 

 

 

xx….xx 

“xx….xx” is a

 

4 - 16 digit string of alphanumeric characters (in capital or lower case) 

 

Cancel authentication by PIN. 

 

Restore the default settings PIN=“1234”. 

 

Inquire the current PIN. 

PROMPT= 

 

This command is used to decide whether status messages are prompted when Setup 
commands are executed. The status messages are: OK/ERROR for command 
execution, or CONNECT/DISCONNECT/Try Connect Device for connection status. 

(Default) 

Prompt result messages. 

 

Not prompt result messages. 

 

Inquire the current setting. 

RECONNECT= 

 

The command is used to re-connect the lost link for the Master adapter. 

 

Inquire the current setting. 

(Default) 

Re-connect is disable 

 

Re-connect is Enable 

ROLE= 

 

This command is used to specify whether the adapter is in the master or slave mode. If 
the device mode is changed, the adapter will reboot and all paired addresses will be 
cleared. The command is available when the adapter is in DIP=N status. The command 
will need 1 second delay. 

 

Set the adapter to the master mode. 

(Default) 

Set the adapter to the slave mode. 

Summary of Contents for S2B2232I

Page 1: ...Mac Android Interface type RS232 Chipset CSR BlueCore4 model BC417 Baud Rate 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 921600bps Data bits 7 or 8 Stop bits 1 or 2 Parity None odd eve...

Page 2: ...with iPad iPod No it will not work with iPads iPods due to the restrictions Apple put on their Bluetooth chipset however it does work with most other Bluetooth enabled smartphones tablets and devices...

Page 3: ...gs can be configured using any terminal software such as TeraTerm Putty or Hyper Terminal Only some settings can be configured by DIP switches Please see the Setup Guide and below parameter table for...

Page 4: ...19200 010 38400 011 57600 100 115200 101 230400 DB9 Female connector pin configuration Pin Signal DTE Direction DCE Direction Description 1 CD Input Output Not connected 2 TxD Output Input Transmitte...

Page 5: ...t appear before the command is entered and a minimum of 2000ms data silence after the command is entered The time interval between each entered characters should be 1 sec 1 sec 1 sec 2 sec Inquire the...

Page 6: ...te slave address If the adapter is in the Slave mode this command is a filter condition to accept the inquiry of the Master device Notice The DEVICE command only works with the CONNECT command to manu...

Page 7: ...a PIN The default PIN is 1234 Paired adapters should have a same PIN The length must be 4 16 alphanumeric characters Notice SSP secure simple pairing is supported which means that the master will not...

Page 8: ...es These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Reviews: