The following steps outline the initial set
-
up of your USC K
-
Valve.
After completing steps on prior page for set
-
up of the surge hopper:
1.
Unpack K
-
Valve and associated equipment.
2.
There are two main assemblies to the K
-
valve (K
-
valve, & discharge chute) and
associated nuts bolts, etc.
3.
Attach the K
-
valve to the flange on the bottom of the air gate (shipped on the
hopper). Use 3/8—16 X 1 1/4” grade 8 bolts with flange nuts
4.
Adjust the output side of the K
-
valve such that it faces out the side desired by
loosening and re
-
tightening the clamp ring.
5.
Attach the flange on the discharge chute to the flange on the K
-
valve. Use 3/8
-
16 X
1 1/4” grade 8 bolts and flange nuts.
6.
Attach two support cables from the spout to the rim of the hopper. Use 3/8
-
16 X 1
1/4” grade 8 flange bolts and flange nuts.
NOTE: Hopper legs
are not shown in this
view.
3