US Water Systems 400-USUV-10 Owner'S Manual Download Page 4

Water Quality and Minerals 

Level 

Iron 

< 0.3 ppm (0.3mg/L) 

Hardness* 

<7 gpg (120 mg/L) 

Turbidity 

< 1 NTU 

Manganese 

< 0.05 ppm (0.05 mg/L) 

Tannins 

< 0.1 ppm (0.1 mg/L) 

UV Transmittance 

> 75% (call factory for recommendations on applica-
tions where UVT < 75%) 

  

 

 

 

 

 

        CAUTION  

Failure to follow these instructions could result in minor or moderate injury.  

• 

Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the controller or lamp connector.  

• 

Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 10" of copper pipe on the outlet of 
your UV chamber.  

 

 

 

 

 

 

       

NOTICE 

 

• 

The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually.  

• 

The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to 
handle the UV system unless they have been given supervision or instruction.  

• 

EXTENSION CORDS: 

If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the 

plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an electrical rating not less than the rating of the system. A 
cord rated for less amperes or watts than this system rating may overheat. Exercise caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use 
damaged extension cords. Examine extension cord before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. 
Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the 
plug and pull to disconnect.  

• 

SYSTEM PROTECTION: 

To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly recommended.  

• 

The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, Chapter 1, Subchapter J, Radiologi-
cal Health.  

• 

Read and understand the Owner's Manual before operating and performing any maintenance on this equipment. 

 

 
1.3 Water Chemistry  

Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation: 

 

 

 

 

 

 

 

 

 

 

 

 

* Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically. If total 
hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess of those mentioned above, prop-
er pre-treatment is recommended to correct these water problems prior to the installation of your UV disinfection system. These water 
quality parameters can be tested by your local dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the 
UV disinfection system to operate as intended.  

 

 

WA R N I N G

During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recom-
mended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate 
this condition, a temperature management valve can be installed at the outlet of your UV system.

Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void the 
manufacturer's warranty.

Summary of Contents for 400-USUV-10

Page 1: ...ance Class B Powered by US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Owner s Manual Visit us online at www uswatersystems com REVISION 1 0 REVISION DATE September 29 2015 Models 400 USUV 10 400 USUV 20 400 USUV 30 ...

Page 2: ...hould US Water Systems replacement lamps be used Use of widely available non genuine replacement lamps has been shown to damage the control module of US Water Systems UV disinfection equipment An increasing number of calls to US Water Systems Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safety...

Page 3: ...d be hot and should not be touched without care This symbol indicates there is a potential for VERY hot water when flow is started This symbol indicates there is Mercury present Hg Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situ...

Page 4: ... heat and sharp edges Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to th...

Page 5: ...nt life 9000 hours S200RL HO 400 USUV 10 S410RL HO 400 USUV 20 S600RL HO 400 USUV 30 4 Retaining Nut RN 001 Used on all systems 5 Controller for 100 240V 50 60HZ models only BA ICE CL 400 USUV 10 400 USUV 20 BA ICE C 400 USUV 30 6 IEC replacement power cords for controller sold separately 260010 400 USUV 10 400 USUV 20 400 USUV 30 7 Mounting Brackets Clamp Assembly 410067 Used on all systems 5 Gen...

Page 6: ...e exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfection system should be the last treatment the water receives before it reaches the faucet Procedure 1 Figure 2 shows the installation of a typical disinfection system and the related components that may be used...

Page 7: ...ned to be installed in one direction only Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor Refer to Figure 4 Note DO NOT solder connections while attached to the system as this could damage the O ring seals 4 Mount the US WATER SYSTEMS ICE controller horizontally to the wall near the UV chamber Ideally place the con troller above the chamber and away...

Page 8: ...nywhere in the house for a minute to flush out the warm water 3 2 Disinfection Procedure UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemi cally disinfected to ensure that the plumbing system is free from ...

Page 9: ...ment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1 0 mg L typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg L chlorine solution recommended for the disinfection of distribution systems known to be contaminated DO NOT consume water until complete system has been flushe...

Page 10: ...us operation approximately one year in order to ensure adequate disinfection Procedure 2 3 4 10 MINS 1 2 Shut off the water line to chamber and release system pressure before servicing Disconnect main power source and allow the unit to cool for 10 minutes Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector Remove the lamp in upward direction from the chambe...

Page 11: ...LR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched or cracked then re place the sleeve Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber Slide supplied O rings onto each end of the quartz sleeve Reinstall the top and bottom retaining nuts floating spring a...

Page 12: ... reset button for 5 seconds which is located on the left side of the controller Each time the timer reset button is pressed the controller alarm is deferred seven days Once the final 7 day de ferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller tim er refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even tho...

Page 13: ...urged Unit Leaking Water Problem with O ring seal on retaining nut and or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive humidity cold water Check location of disinfection system and control humidity Inadequate inlet outlet port connec tions Check thr...

Page 14: ...Specifications Standard and Validated Section 7 Manufacturer s Dose Flow Chart 18 400 USUV 10 400 USUV 20 400 USUV 30 ...

Page 15: ...3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 8 x 3 2 x 2 5 Inlet Outlet Port Size Combo 3 4 FNPT 1 MNPT Combo 3 4 FNPT 1 MNPT 1 MNPT Shipping Weight 5 4 kg 12 lbs 7 7 kg 17 lbs 8 6 kg 19 lbs Electrical Voltage 100 240V 50 60Hz 100 240V 50 60Hz 100 240V 50 60Hz Power Consumption 35 W 60 W 78 W UV Lamp Watts 25 W 46 W 58 W Total Running Time Yes Yes Yes Maximum Operating Pressure 8 62 bar 125 psi 8 62 bar ...

Page 16: ...g that purchaser uses bulbs and sleeves purchased from US Water During this time US WATER SYSTEMS will repair or replace at its option any defective parts covered by the warranty Please return the defective part to process your claim If this product is used in a commercial application the warranty on the chamber is 10 years One Year Limited Warranty for UV lamps Sleeves and UV Sensors US WATER SYS...

Reviews: