Section 1 Safety Information 

 

 
Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in 
this manual. Failure to do so could result in serious personal injury or damage to the equipment. 

 

Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any 

manner other than that specified in the installation manual. 

 

1.1 Potential Hazards: 

 

Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.  

This symbol indicates safety glasses with side protection is 
required for protection against UV exposure.  

This symbol indicates safety glasses with side protection is 
required for protection against UV exposure. 

 

This symbol indicates gloves must be worn.  

Warning:

 This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive h arm. 

 

1.2 Safety Precautions:  

This symbol indicates safety boots must be worn. 

This symbol indicates the operator must read all available docu-
mentation to perform required procedures.  

This symbol indicates the plumber must use copper piping.  

This symbol indicates that the system should only be connected 
to a properly grounded, grounding-type controller receptacle that 
is protected by a Ground Fault Circuit Interrupter (GFCI).  

Waste electrical and electronic equipment (WEEE). This symbol indicates that 
you should not discard wasted electrical or electronic equipment (WEEE) in the 
trash. For proper disposal, contact your material close to the system. local recy-
cling/reuse or hazardous waste center.  

This symbol indicates not to store any combustible or flamma-
ble material close to the system.  

This is the safety alert symbol. Obey all safety messages that follow 
this symbol to avoid potential injury. When on the equipment, refer to 
the Operational and Maintenance manual for additional safety  

This symbol indicates a risk of electrical shock and/or electrocution 
exists.  

This symbol indicates the marked equipment may contain a compo-
nent that can eject forcibly. Obey all procedures to safely depressur-
ize.  

This symbol indicates the system is under pressure.  

This symbol indicates there is a potential UV hazard. Proper protec-
tion must be worn.  

This symbol indicates the marked item could be hot and should not 
be touched without care.  

This symbol indicates there is a potential for VERY hot water when 
flow is started. 

This symbol indicates there is Mercury present. 

Hg 

 

Failure to follow these instructions will result in serious injury or death.   

 

Electric Shock:

 

To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a situation is encountered that is explicitly addressed by the 

provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, refer to an authorized service facility. 

 

 

GROUNDING:

 

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This system is 

equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes 

and ordinances. 

 

Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is 

properly grounded. DO NOT modify the plug provided with this system - if it does not fit in the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system. 

 

 

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this 

system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI). Inspect operation of GFCI as per manufacturer's suggest-

ed maintenance schedule. 

 

 

DO NOT 

operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner. 

 

 

DO NOT 

use this disinfection system for other than intended use (potable water applications). The use of attachments not recommended or sold by the manufacturer / distributor may cause an unsafe condition. 

 

 

DO NOT 

install this disinfection system where it will be exposed to the weather or to temperatures below freezing. 

 

 

DO NOT 

store this disinfection system where it will be exposed to the weather.  

 

DO NOT 

store this disinfection system where it will be exposed to temperatures below freezing unless all water has been drained from it and the water supply has been disconnected. 

 

Summary of Contents for 400-USUV-10

Page 1: ...ance Class B Powered by US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Owner s Manual Visit us online at www uswatersystems com REVISION 1 0 REVISION DATE September 29 2015 Models 400 USUV 10 400 USUV 20 400 USUV 30 ...

Page 2: ...hould US Water Systems replacement lamps be used Use of widely available non genuine replacement lamps has been shown to damage the control module of US Water Systems UV disinfection equipment An increasing number of calls to US Water Systems Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safety...

Page 3: ...d be hot and should not be touched without care This symbol indicates there is a potential for VERY hot water when flow is started This symbol indicates there is Mercury present Hg Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situ...

Page 4: ... heat and sharp edges Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to th...

Page 5: ...nt life 9000 hours S200RL HO 400 USUV 10 S410RL HO 400 USUV 20 S600RL HO 400 USUV 30 4 Retaining Nut RN 001 Used on all systems 5 Controller for 100 240V 50 60HZ models only BA ICE CL 400 USUV 10 400 USUV 20 BA ICE C 400 USUV 30 6 IEC replacement power cords for controller sold separately 260010 400 USUV 10 400 USUV 20 400 USUV 30 7 Mounting Brackets Clamp Assembly 410067 Used on all systems 5 Gen...

Page 6: ...e exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfection system should be the last treatment the water receives before it reaches the faucet Procedure 1 Figure 2 shows the installation of a typical disinfection system and the related components that may be used...

Page 7: ...ned to be installed in one direction only Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor Refer to Figure 4 Note DO NOT solder connections while attached to the system as this could damage the O ring seals 4 Mount the US WATER SYSTEMS ICE controller horizontally to the wall near the UV chamber Ideally place the con troller above the chamber and away...

Page 8: ...nywhere in the house for a minute to flush out the warm water 3 2 Disinfection Procedure UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemi cally disinfected to ensure that the plumbing system is free from ...

Page 9: ...ment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1 0 mg L typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg L chlorine solution recommended for the disinfection of distribution systems known to be contaminated DO NOT consume water until complete system has been flushe...

Page 10: ...us operation approximately one year in order to ensure adequate disinfection Procedure 2 3 4 10 MINS 1 2 Shut off the water line to chamber and release system pressure before servicing Disconnect main power source and allow the unit to cool for 10 minutes Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector Remove the lamp in upward direction from the chambe...

Page 11: ...LR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched or cracked then re place the sleeve Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber Slide supplied O rings onto each end of the quartz sleeve Reinstall the top and bottom retaining nuts floating spring a...

Page 12: ... reset button for 5 seconds which is located on the left side of the controller Each time the timer reset button is pressed the controller alarm is deferred seven days Once the final 7 day de ferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller tim er refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even tho...

Page 13: ...urged Unit Leaking Water Problem with O ring seal on retaining nut and or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive humidity cold water Check location of disinfection system and control humidity Inadequate inlet outlet port connec tions Check thr...

Page 14: ...Specifications Standard and Validated Section 7 Manufacturer s Dose Flow Chart 18 400 USUV 10 400 USUV 20 400 USUV 30 ...

Page 15: ...3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 8 x 3 2 x 2 5 Inlet Outlet Port Size Combo 3 4 FNPT 1 MNPT Combo 3 4 FNPT 1 MNPT 1 MNPT Shipping Weight 5 4 kg 12 lbs 7 7 kg 17 lbs 8 6 kg 19 lbs Electrical Voltage 100 240V 50 60Hz 100 240V 50 60Hz 100 240V 50 60Hz Power Consumption 35 W 60 W 78 W UV Lamp Watts 25 W 46 W 58 W Total Running Time Yes Yes Yes Maximum Operating Pressure 8 62 bar 125 psi 8 62 bar ...

Page 16: ...g that purchaser uses bulbs and sleeves purchased from US Water During this time US WATER SYSTEMS will repair or replace at its option any defective parts covered by the warranty Please return the defective part to process your claim If this product is used in a commercial application the warranty on the chamber is 10 years One Year Limited Warranty for UV lamps Sleeves and UV Sensors US WATER SYS...

Reviews: