11
PANEL CONTROLS
The blowers and automatic fuel supply are controlled from a panel on the top of the unit. The control panel functions
are a follows.
A. ON/OFF SWITCH (“POWER” BUTTON)
•
When pushed, the stove will automatically ignite. No other fire starter is necessary. The igniter will stay on for at
least 10 and up to 12 minutes, depending on when Proof of Fire is reached. The fire should start in approximately
5 minutes.
•
The red light located above the “POWER” button will turn green when pressed and remain green until the stove
is turned off.
• After pushing “POWER”, the auger motor is on for 3.5 minutes, off for 1 minute. During the remainder of the start-
up period, the auger motor operates on the heat range “1” setting.
•
During start up the heat level advance (Up and Down keys) will change the heat range indicator level
accordingly, but there is no change in the stoves operating conditions until start-up is completed.
•
During start-up ignition must occur within 12 minutes or the stove will error out and show E4.
• During the start-up phase, the Mode key does not function.
B. LEVEL / TEMP ARROW BUTTONS
•
These buttons when pushed will set the pellet feed rate, hence the heat output or heat range of your stove.
•
The levels of heat output will incrementally change on the bar graph starting from heat range “1” to heat range
“5”.
C. °C / °F Button
•
The °C / °F button changes the two digit display from degrees Celsius to degrees Fahrenheit.
D. MODE (M/T) BUTTON
•
The Mode of the stove can be switched between manual and controlled with a Thermostat. Separate LEDs to
the left of the two digit display indicate the mode of operation – Manual or T-Stat. The stove has to be in normal
operation to be switched from Manual to T-Stat mode.
• Manual mode operates according to the 5 set levels of feed on the bar graph from heat range “1” to heat
range “5”.
•
T-Stat mode works as follows:
• The stove has a built in Thermostat into the controls of the appliance. The temperature sensor for the T-Stat is
located on the back of the stove behind the display board.
•
Once the stove has gone into run mode the stove can be switch into T-Stat mode.
•
The Up and Down Level / Temp Arrow buttons are used to change the desired set-point temperature. Once
the desired temperature is reached the two digit display will flash for four seconds and reset to the actual room
temperature.
•
Once the stove reaches within 3°F of the desired temperature set point, it returns to the heat range that the
stove was set on before it was switched to T-Stat mode (if the stove was running on heat range “5” when
switched to T-stat mode when it gets within 3°F of the set point it will return to heat range “5”).
•
Once the stove reaches the desired set-point, the stove will drop to heat range “1”.
•
When room temperature drops below desired set-point the stove will ramp back up until it reaches the desired
temperature.
CONTROLS
Control Panel
Summary of Contents for Ashley AP5710
Page 30: ...Notes...