US drives AC REGEN RGB-0200-0030-N1 Instruction Manual Download Page 17

 

WARRANTY 

 

US Drives, Inc. warrants the equipment described in this manual for thirty-six (36) months from 
the  day  of  purchase,  not  to  exceed  forty  (40)  months  from  date  of  manufacture.    US  Drives 
further warrants that such goods are free of defects in materials and workmanship. 
 
If the goods fail to perform to US Drives published specifications, then the Buyer must contact 
US Drives  to  obtain  a  Material  Return  Authorization  (MRA),  prepare  the  goods  for  shipment, 
and return the goods to US Drives for repair or replacement at US Drives Option.  The buyer 
will bear all costs of transportation to and from US Drives factory, risk of loss for goods not at 
US Drives factory, and any cost required to remove or prepare the goods for shipment to US 
Drives factory and to reinstall equipment subsequent to repair.     
 
In no event and under no circumstances shall the manufacturer be liable for: (a) damages and 
failures due to improper use or installation; (b) damage in shipment; (c) damage to abnormal 
conditions  of  temperature,  dust,  or  corrosives,  or  failures  due  to  operation  above  rated 
capacities, whether intentional or unintentional; (d) non-authorized service, repair, modification, 
transportation  or  installation.  Nor  shall  the  manufacturer  ever  be  liable  for  consequential  or 
incidental damages including any lost profits or lost savings. 
 
There  are  no  other  warranties,  expressed  or  implied,  which  extend  beyond  that  described   
herein.   The  warranty  set  forth is  exclusive and  no other  warranty,  whether  written  or  oral,  is 
expressed  or  implied.    US  Drives  specifically  disclaims  the  implied  warranties  of 
merchantability and fitness for a particular purpose. 
 
The  warranty  is  effective  only  if  a  written  notification  of  any  claim  under  this  warranty  is 
received by US Drives at the address indicated below within thirty (30) days of recognition of 
defect by buyer. 
 
US Drives reserves the right to make changes and improvements in its goods without incurring 
any  obligation  to  similarly  alter goods  previously  purchased.    US Drives  neither  assumes  nor 
authorizes any representative or any other person to assume for US Drives any other liability in 
connection with the sale or any shipment of its goods. 
 
 
 

US DRIVES INC. 

2221 Niagara Falls Boulevard 

P.O. Box 281 

Niagara Falls, NY 14304-0281 

Tel: (716) 731-1606   Fax: (716) 731-1524 

 

Visit us at 

www.usdrivesinc.com

 

Summary of Contents for AC REGEN RGB-0200-0030-N1

Page 1: ...REGENERATIVE DC COMMON BUS SUPPLY 15 HP TO 1300 HP INSTRUCTION MANUAL ...

Page 2: ...ill be subject to vibration then the enclosure should be shock mounted Safety Warnings Regenerative modules like all electrical equipment in industry if not properly installed and operated can cause personal injury Always use common sense when working around electrical equipment Make sure you read this manual before any work on the unit begins Never work on this product if you are tired or under t...

Page 3: ...y may result in personnel injury and or equipment damage WARNING An incorrectly applied or installed AC REGEN can result in component damage or a reduction in product life Wiring or application errors such as under sizing the motor incorrect or inadequate AC supply or excessive ambient temperatures may result in damage to the Drive or motor WARNING This AC REGEN contains ESD Electrostatic Discharg...

Page 4: ...l attributes Mounting Though hole or panel mount Nema Rating Type 1 IP20 as standard Type 12 IP54 optional Construction Steel construction reduces E M I Control I O 2 Digital Inputs Regen Enable Regen Reset 2 Digital Outputs Form C dry contacts rated 115Vac 5A 30Vdc 3 5A 1 meter output Use with 100 A movement analog meter 24Vdc source Use to power operator pushbuttons and US Drives option boards 2...

Page 5: ...uses Ferraz Shawmut A50P A60X Bussmann FWH 4 Total Power Loss shown is for continuous operation at full regeneration Table 2 Class 400 Regenerative DC Common Bus Supply Models Typical Voltage 380 415 480 VAC 380 500VAC 10 to 10 Frame Designation NEMA 1 IP20 Catalog Number Drive HP2 Continuous Regen DC Bus Current Amps Continuous Motoring DC Bus Current Amps AC Current Amps Maximum Recommended AC L...

Page 6: ...240 244 225 350 1538 RGB 0500 0300 N1 350 300 342 312 450 1900 RGB 0500 0360 N1 400 360 390 355 600 2282 SIZE 3 RGB 0500 0480 N1 500 480 488 439 700 3026 RGB 0500 0540 N1 600 540 586 536 800 3390 RGB 0500 0600 N1 700 600 683 625 900 3770 RGB 0500 0720 N1 800 720 781 714 1000 4514 RGB 0500 0840 N1 900 840 878 804 1200 5250 RGB 0500 0960 N1 1000 960 976 893 1200 6002 RGB 0500 1080 N1 1300 1080 1269 ...

Page 7: ...cal damage sustained during shipment If damaged file a claim with the shipper and return for repair following the procedures outlined on the back cover If no damage is observed remove all shipping restraints and padding Check AC REGEN nameplate data for conformance with the AC power source and motor DETERMINING CONTROL LOCATION The AC REGEN is suitable for most well ventilated factory areas where ...

Page 8: ...on transformer is required are as follows 1 If the AC input power system does not have a neutral or one phase referenced to ground an isolation transformer with the neutral of the secondary grounded is highly recommended If the line to ground voltages on any phase can exceed 125 of the nominal line to line voltage an isolation transformer with the neutral of the secondary grounded is always requir...

Page 9: ...point Grounding Sensitive Circuits It is critical to control the paths through which high frequency ground currents flow Sensitive circuits should not share a path with such currents Control and signal conductors should not be run near or parallel to power conductors Power Cabling Input and Output power connections are made through the power terminal block and power ground stud The actual AC REGEN...

Page 10: ...rom the drive before drilling and punching holes to avoid metal dust inside the drive enclosure Failure to do so will cause damage to the drive For through panel mounting customer is to seal for gap on all side of cutout Provided by customer aluminum angle 1 x 1 x 0 050 can be used to attach to all sides of drive to help seal and secure the drive Figure 2 AC Regen Mounting Information Size 1 Nema ...

Page 11: ...om the drive before drilling and punching holes to avoid metal dust inside the drive enclosure Failure to do so will cause damage to the drive For through panel mounting customer is to seal for gap on all side of cutout Provided by customer aluminum angle 1 x 1 x 0 050 can be used to attach to all sides of drive to help seal and secure the drive Figure 2 2a AC Regen Mounting Information Size 2 Nem...

Page 12: ...es to avoid metal dust inside the drive enclosure Failure to do so will cause damage to the drive For through panel mounting customer is to seal for gap on all side of cutout Provided by customer aluminum angle 1 x 1 x 0 050 can be used to attach to all sides of drive to help seal and secure the drive Size 3 enclosure can also be free standing with optional floor stand kit from US Drives Inc Figur...

Page 13: ...REGENERATIVE DC COMMON BUS SUPPLY 11 Figure 3 Size 1 2 3 Recommended Power Wiring ...

Page 14: ...dc logic TB1 TERM 3 Regen Reset 24 Vdc logic TB1 TERM 4 Control circuit common TB2 TERM 1 2 Normally open contact energized when Regen is ON TB2 TERM 3 4 Normally open contact energized when Regen Precharge is complete Figure 4 Main Control Board Terminal Block Layout Table 5 Terminal Blocks Description for Control Board ...

Page 15: ...rmal The first fault is automatically cleared after the control power supply stabilizes If a second fault occurs within a minute the fault is latched and clearing it requires a Regen reset LEDs at Start and Reset While the AC Regen is detecting the line frequency all LEDs except the Regen Active LED will be lit If the AC Regen reset line is held active the drive will rapidly flash every 100msec al...

Page 16: ...lease note if an on board fuse soldered to the control board is open do not attempt to replace it An open on board fuse indicates a damaged board Visual Check Check all fuses boards wire harnesses connectors bus bars and enclosure walls for discoloration Ohmic Check Check IGBT personality boards for the following Burnt or discolored resistors R1 R2 R3 6 sets per Regen Shorted D1 D2 using meter set...

Page 17: ...ated capacities whether intentional or unintentional d non authorized service repair modification transportation or installation Nor shall the manufacturer ever be liable for consequential or incidental damages including any lost profits or lost savings There are no other warranties expressed or implied which extend beyond that described herein The warranty set forth is exclusive and no other warr...

Page 18: ... in U S A THE HIGH HORSEPOWER DESIGN EXPERTS US Drives Inc 2221 Niagara Falls Boulevard P O Box 281 Niagara Falls NY 14304 0281 Tel 716 731 1606 Fax 716 731 1524 Visit us at www usdrivesinc com Products Designed and Manufactured In The United States of America ...

Reviews: